Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow
required for safe operation of the equipment is not compromised.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
Reliable Grounding - Reliable grounding of rack mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (e.g.
use of power strips).
Installation & Operation:
This equipment must be grounded. The power cord for product should be connected to a socket-outlet with
earthing connection.
Cet équipement doit être mis à la terre. La fiche d'alimentation doit être connectée à une prise de terre
correctement câblée
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National
Electrical Code and NFPA 75.
Peut être installé dans des salles de matériel de traitement de l'information conformément à l'article 645 du
National Electrical Code et à la NFPA 75.
The machine can only be used in a restricted access location and must be installed by a skilled person.
Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT.
This product is intended to be supplied by a Listed Power Adapter or DC power source, rated 12-24Vdc, 17.5-
8A minimum, Tma = 70
°
C, and the altitude of operation = 5000m.
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding) is
very important to protect the equipment against the harmful effects of external noise and to reduce the risk of
electrocution in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire after
turning off the power. A ground wire is required and the part connecting the conductor must be greater than
4 mm2 or 10 AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équ
ipement à la terre.
Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre les
effets néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil.
Un câble de mise à la terre est requis et la zone reliant les sections du conducteur doit faire plus de 4 mm2
ou 10 AWG.
Summary of Contents for LEC-2290H
Page 9: ...LEC 2290H User Manual 9 Warranty Policy 106...
Page 17: ...LEC 2290H User Manual 17 Storage Expansion DDR4 DDR4 CPU M 2 DIMM1 DIMM2 MSATA1 MPCIE1 JNGFF1...
Page 18: ...LEC 2290H User Manual 18 IPMI BMC Card PCIe...
Page 51: ...LEC 2290H User Manual 51...
Page 59: ...LEC 2290H User Manual 59...
Page 61: ...LEC 2290H User Manual 61...
Page 64: ...LEC 2290H User Manual 64...
Page 66: ...LEC 2290H User Manual 66...
Page 73: ...LEC 2290H User Manual 73...
Page 80: ...LEC 2290H User Manual 80...
Page 84: ...LEC 2290H User Manual 84 NOTE Control various DMI functions Just keep it at default settings...
Page 85: ...LEC 2290H User Manual 85...