![Lanner HCP-72i1 User Manual Download Page 104](http://html1.mh-extra.com/html/lanner/hcp-72i1/hcp-72i1_user-manual_3605828104.webp)
104
www.lannerinc.com
Scenario 2: The Bottom Board Used as the Management Port, and Return the Device 2
and 3 to the Upper Board.
Remove the Device 2 and 3 from the Bottom Board
For the Bottom Board, please issue the following command:
~#sh ./stop_lan_device.sh 0 rescue
Switch the downstream port 0x10, 0x11 into the Upper Board.
For the Bottom Board, please issue the following commands accordingly:
~# sh ./en_management.sh 0
~# sh ./recover_slot.sh 0
The Upper Board rescans to see that if there is any new devices added or not.
In the Upper Board, please issue the following command:
~# echo 1 > /sys/bus/pci/rescan
Instructions of Commands
<recover_slot.sh>
Paratmeters:
recover_slot.sh slot_number
Function Description:
Return the devices that had been switched.
Main Commands of the Script:
~# ./vs_test “ Upstream port BusID:DeviceID:FunctionID “ VS_ID recover
Summary of Contents for HCP-72i1
Page 9: ...9 www lannerinc com Chapter 1 Introduction...
Page 14: ...14 www lannerinc com Chapter 2 System Components...
Page 15: ...15 www lannerinc com Chapter 2 System Components Mechanical Drawings Unit mm...
Page 18: ...18 www lannerinc com Chapter 3 Motherboard Information...
Page 26: ...26 www lannerinc com Chapter 4 Hardware Installation...
Page 35: ...35 www lannerinc com Chapter 5 BIOS Setup...
Page 74: ...74 www lannerinc com NETWORK Device BBS Priorities 1st Boot set boot priority...
Page 77: ...77 www lannerinc com Chapter 6 IPMI Navigation...
Page 97: ...97 www lannerinc com Chapter 7 About the PCIe Switch Feature of HCP 72i1...
Page 116: ...116 www lannerinc com...