background image

CPU and the Heat Sink Installation

The FW-7585 sever system is powered by the MB-7585 

sever board, which comes with one ZIF type LGA1150 

CPU socket.
Follow the procedure bellow for installing a CPU

Press the socket lever and release it from the 

1. 

retention tab.
Lift the socket lever and then the plate.

2. 

Remove the CPU socket cap.

3. 

Align the notches in the CPU base and the tabs on the 

4. 

socket. The CPU should fit perfectly into the socket. 

Note that the CPU fits in the socket in only one 

direction.
Close the CPU cover plate by lightly pressing down on 

5. 

the CPU cover plate while closing the socket lever.
Peel off the sticker on the CPU to expose the thermal 

6. 

compound.
Align the heatsink’s four mounting screws with the 

7. 

mounting holes in the chassis. Carefully place the 

heatsink on the CPU. Tighten each heatsink screw 

a little at a time to ensure that the CPU stays level. 

Tighten each set of diagonally opposed screws at a 

time.

2

3

1

 

5

4

6

Note

:  

The CPU heat sink can only be installed in only 

1. 

one orientation as  shown in the picture.

 To protect the CPU socket pins, retain the CPU 

2. 

cap when the CPU is not installed.

7

Summary of Contents for FW-8759

Page 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 8759 V1 0 User s Manual August 14 2015...

Page 2: ...responsibility for its use nor for any infringements upon the rights of third parties that may result from such use Acknowledgement Intel Pentium and Celeron are registered trademarks of Intel Corp Mi...

Page 3: ...he room in which you choose to operate your system has adequate air circulation Ensure that the chassis cover is secure The chassis design allows cooling air to circulate effectively An open chassis p...

Page 4: ...dir l quipement une temp rature de fonctionnement acceptable sans circulation adapt e V rifiez que votre site propose une circulation d air ad quate V rifiez que le couvercle du ch ssis est bien fix L...

Page 5: ...Version Date Y M D Description 0 1 2014 05 09 Preliminary 0 2 2014 08 01 Take off Fan4 Take off LED2 from the motherboard 1 0 2015 08 14 Official release...

Page 6: ...lation 20 System Memory Installation 20 Hard Disk Installation 20 CPU and the Heat Sink Installation 22 CompactFlash Card Installation 23 IPMI Card Installation 23 Front Ethernet Module Installation 2...

Page 7: ...ndate one Ethernet module to provide additional 2 10GbE or 8 GbE LAN ports Please refer to the chart below for a summary of the system s specifications System Specifications Form Factor Rackmount 1U P...

Page 8: ...rivers and user s manual CD Optional Accessories The system has a variety of optional accessories visit the following website for more information http www lannerinc com products x86 network appliance...

Page 9: ...nsmission Off The port is not linking SPEED Green Amber Amber The connection speed is 1000Mbps Green The connection speed is 100Mbps Off The connection speed is 10Mbps 3 pairs LAN1 LAN2 LAN3 LAN4 LAN5...

Page 10: ...M428B 4 GbE RJ45 Intel i350AM 4 N A NCS2 ISM405A 4 GbE SFP Fiber Intel I350 AM4 2 pairs NCS2 ISM406A 4 GbE SFP Fiber Intel I350 AM4 N A NCS2 ISM802A 8 GbE SFP Fiber Intel i350AM 4 N A NCS2 IXM205A 2 1...

Page 11: ...can be turned on automatically when the temperature exceeds the set threshold R4 Redundant Power Supply The 300W redundant power supply is hot swappable and can be withdrawn and replaced when the ala...

Page 12: ...3 Motherboard Information Block Diagram The block diagram depicts the relationships among the interfaces or modules on the motherboard Please refer to the following figure for your motherboard s layou...

Page 13: ...to the following picture as a reference of the pin assignments and the internal connectors CF1 COMB2 J11 OPMA1 FAN3 LCM1 J6 SATA1 SATA3 SATA2 DIO1 ATX2 FAN2 PCIESLOT1 DIMM2 DIMM1 J3 J4 J5 J1 PCIESLOT2...

Page 14: ...s Connector Pinouts Fan Connectors FAN1 FAN2 FAN3 The 5 pin connector is for connecting the CPU and system fans It comes with the smart fan feature by which the fans could be monitored and turned on w...

Page 15: ...e cable to connect this 10 pin ISP in header connector the user can update the SPI Flash soldered on board PSU PMBUS and TTL Function Connectors CON3 Pin No Signals 1 PWR_BTIN_N 2 GND 2 4 6 8 10 1 3 5...

Page 16: ...he software reset can be programmed to reset a software to its default setting ATX Power Connector ATX1 ATX2 Find the proper orientation when inserting the plugs for the supply plugs are designed to f...

Page 17: ...Signal Pin No Signal B1 P12V A1 B2 P12V A2 P12V B3 P12V A3 P12V B4 GND A4 GND B5 SLOT2SMBCLK A5 B6 SLOT2SMBDAT A6 B7 GND A7 B8 P3V3 A8 PCIE1_IO_GP B9 A9 P3V3 B10 P3V3SB A10 P3V3 B11 PCIWAKE A11 PCIES...

Page 18: ...EG_TX 6 A42 GND B43 GND A43 PEG_RX 6 B44 GND A44 PEG_RX 6 B45 PEG_TX 7 A45 GND B46 PEG_TX 7 A46 GND B47 GND A47 PEG_RX 7 B48 A48 PEG_RX 7 B49 GND A49 GND Front LCD Module Connector LCM1 It is for conn...

Page 19: ...der CONN4 It is for detecting case open event Digital Input Output Port DIO1 Pin No Signal 1 CASEOPEN 2 GND 2 1 2 10 1 9 Pin No Signal Pin No Signal 1 GPO_1 2 GPI_1 3 GPO_2 4 GPI_2 5 GPO_3 6 GPI_3 7 G...

Page 20: ...ternet applications To install the memory Open the DIMM slot latches 1 Install the DIMM 2 Note All DIMMs installed must be the same speed 1 DDR3 DDR3L 1066 1333 1600MHz unbuffered ECC or non ECC Do no...

Page 21: ...try It is recommended that the HDD is installed in this orientation on the system Note Please note the original package only includes one SATA cable data You need to order another cable SATA data cab...

Page 22: ...in the socket in only one direction Close the CPU cover plate by lightly pressing down on 5 the CPU cover plate while closing the socket lever Peel off the sticker on the CPU to expose the thermal 6...

Page 23: ...ing toward the connector Push the card to insert into the connector 2 IPMI Card Installation FW 8759 provides one OPMA slot for Lanner IPMI card AST2300 Follow the procedure bellow for installing an I...

Page 24: ...driver is highly recommended Riser Card Installation optional The FW 8759 provides one PCIex8 Generation 3 slot for installing the riser card for rear expansion capability Follow this procedure bellow...

Page 25: ......

Page 26: ...ystem off and then back on Do this last option only if the first two failed The Setup program is designed to make it as easy to use as possible Being a menu driven program it lets you scroll through t...

Page 27: ...right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accom...

Page 28: ...and Minus keys to change the value of the selected option A description of the selected item appears on the right side of the screen The settings are described below Item Selection Intel Hyper thread...

Page 29: ...physical storage devices AHCI Mode Set to AHCI mode when you want the SATA hard disk drives to use the AHCI Advanced Host Controller Interface The AHCI allows the onboard storage driver to enable adv...

Page 30: ...sequence hard disk drive initialization and spin up set to control whether each specific drive will spin up USB Configuration Setting You can use this screen to select options for the USB Configurati...

Page 31: ...tected the USB control er legacy mode is disabled Enabled Enable the support for USB devices on legacy operating system Disabled Disable this function USB 3 0 Support Enable or disable USB3 0 support...

Page 32: ...iption Device reset time out This option sets the reset timing for the USB Mass Storage to be initial ized Device power up delay This option sets the power up tim ing for the USB Mass Storage to be in...

Page 33: ...equest address of serial port 0 and 1 Serial Port 0 is the console port on the front panel whereas serial port 1 is the COMB1 pin header item Selection Enabled Disabled Set this value to prevent the s...

Page 34: ...you to configure the smart fan feature You can manually turn on the fans or set the target CPU temperature at which the fans will start running if the fan is not yet turned on And the fans can also b...

Page 35: ...ment PXE allows you to boot computers using a network interface independently of data storage devices like hard disks or installed operating systems Enable or disable this function on the management p...

Page 36: ...ngs COM0 is the console port whereas COM1 refers to the iAMT port LAN8 on the front panel see Front Panel Features in Chapter 1 Introduction The Intel iAMT utilize Out of Band OOB access to allow remo...

Page 37: ...er an AC power interruption Power on When setting to Always on the system turns on automatically after a power interruption Last State When setting to Last State the system goes into whatever the stat...

Page 38: ...nfiguration In this screen you will be able to configure the boot procedures and the related elements Items Options Setup Prompt Timeout Specify the number of seconds for the boot setup prompt to wait...

Page 39: ...er password you must enter the user password for booting the system and accessing the BIOS menu To set an Administrator User password Select the option item and press Enter 1 From the Create New Passw...

Page 40: ...em configuration changes select this option to leave setup and reboot the computer so the new system configuration parameters can take effect Discard Changes and Reset This option allows you to discar...

Page 41: ...le Redirection of the BIOS menu The following steps illustrate how to use this feature Connect one end of the console cable to console 1 port of the system and the other end to serial port of the Remo...

Page 42: ...r you have enabled the parallel port in the BIOS setting Execution This section contains sample executable programs that you could test on your platform It demonstrates some useful functionality that...

Page 43: ...m during three instances Just on Just on is the brief moment when the internal power supply turns on and booting process starts system off or upon software request during run time Software programmabl...

Page 44: ...se The following conditions are excluded from this 5 warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineering of the product Operation outsi...

Page 45: ...Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04 FDC Fail 05 HDC Fail 06 Bad Slot 0...

Reviews: