The descriped electric fields can be generated locally with the P21 pulser. If it is guided over the 

module near line „Signal1“ as shown in Fig. 7, electric field couples directly into the signal line. A 

functional error occurs - the relay rattles.

If the P21 pulser is moved across the board in the vicinity of line „Signal2“, the interference is much 

less, since a large part of the electric field does not couple into the signal line, but into the GND 

surface in the immediate vicinity (Fig. 8).

Figure 7: Coupling of electric field into signal1

Figure 8: Coupling of electric field near signal2

According to the WEEE Directive 2012/19/EU (Waste of Electrical and Electronic 

Equipment), the following must be observed:

At the end of its service life, this product should be taken to a suitable disposal facili

-

ty for recycling and disposal. Do not dispose of with household waste.

Langer EMV-Technik GmbH will remedy any fault due to defective material or defective manufacture 

during the statutory warranty period either by repair or by delivery of spare parts.

This warranty is only granted on condition that:

- The information and instructions in the user manual have been observed.

The warranty will be forfeited if:

- An unauthorized repair is performed on the product.

- The product is modified.

 -The product is not used for its intended purpose.

- The product is opened.

This document may not be copied, reproduced or electronically processed, either in its entirety or in 

part, without the prior written permission of Langer EMV-Technik GmbH. The management of Langer 

EMV-Technik GmbH assumes no liability for damage that may arise from using this printed information.

6. Information on Recycling and Disposal

7. Customer Service

8. Warranty

Please contact us if you have any queries, hints and suggestions.

Contact us at:

Langer EMV-Technik GmbH 

Noethnitzer Hang 31 

01728 Bannewitz 

GERMANY

Phone:  +49 (0) 351-430093-0

 

Fax: 

+49 (0) 351-430093-22

 

Email: [email protected] 

Internet: www.langer-emv.com

Summary of Contents for EMC-Basic 1 set

Page 1: ...1 www langer emv com User manual EMC Basic 1 set Demonstration Boards Mini Burst Field Generators www langer emv com EN 03 2022 V 1 0...

Page 2: ...5 2 4 Images 5 2 5 Limitations of Liability 5 2 6 Errors and Omissions 5 2 7 Copyright 5 3 Scope of Delivery 6 4 Safety 8 4 1 Intended Use 8 4 2 Reasonably Foreseeable Misapplication 8 4 3 Personnel R...

Page 3: ...nts The user manual must be kept readily available in the immediate vicinity of the product 2 3 Local Safety and Accident Prevention Regulations The applicable local general safety and accident preven...

Page 4: ...ltage 12 V Current input ca 20 mA Sizes L x W x H 140 x 100 x 23 mm P11 Mini Burst Field Generator B P21 Mini Burst Field Generator E Short Description The P11 mini burst field generator creates a mag...

Page 5: ...ic 1 set may only be operated under supervision Damaged or defective devices must not be used The operating and safety instructions for all devices included in the measurement set up must be observed...

Page 6: ...surrounded by GND and deposited in the inner layer with GND Almost no magnetic field can reach around the signal line the assembly is much more resistant to interference Fig 5 Figure 3 Interference co...

Page 7: ...d waste Langer EMV Technik GmbH will remedy any fault due to defective material or defective manufacture during the statutory warranty period either by repair or by delivery of spare parts This warran...

Page 8: ...430093 0 49 0 351 430093 22 mail langer emv de www langer emv com For EMC measurements accompanying the development we offer Generators IC Measurement Technology Near Field Micro Probes Near Field Pr...

Reviews: