In the case of the SF 11 demo board, a gap in the GND surface deliberately allows magnet field to 

pass through the module between the signal line1 and GND. A functional error occurs - the relay 

rattles. The path of the magnetic field lines is shown in Figure 3. (If this test does not lead to a 

functional error, the polarity must be changed at the pulser).

The coupling can be prevented by a „shield“ made of adhesive copper tape: the magnetic field is 

blocked by the eddy currents within the adhesive copper tape. The magnetic field can no longer 

penetrate the assembly, and the SF 11 is immune to interference.

Alternatively, the line „Signal2“ can be activated by switching the switch S2. This line is completely 

surrounded by GND and deposited in the inner layer with GND. Almost no magnetic field can reach 

around the signal line, the assembly is much more resistant to interference (Fig. 5).

Figure 3: Interference control with Pulser P11

Figure 4: Improving the immunity with a piece of adhesive copper tape

5.2  SF 21 - Demo Board E-Field Immunity

If only one single cable is connected to an assembly, the result is a field image as shown in Fig. 6.

The interference current flows into the module, but couples out again capacitively as an electric field 

(electric flux). This decoupling is done from the GND area as well as from all connected components 

and lines. The current decoupling from the signal line in Fig. 6 generates a voltage difference at 

resistor „R“ (This resistor symbolizes the output resistance of an IC output.). This voltage difference 

can lead to the functional error.

Figure 5: Coupling near line signal2

Figure 6: Field image of SF 21 - only one cable connected

Summary of Contents for EMC-Basic 1 set

Page 1: ...1 www langer emv com User manual EMC Basic 1 set Demonstration Boards Mini Burst Field Generators www langer emv com EN 03 2022 V 1 0...

Page 2: ...5 2 4 Images 5 2 5 Limitations of Liability 5 2 6 Errors and Omissions 5 2 7 Copyright 5 3 Scope of Delivery 6 4 Safety 8 4 1 Intended Use 8 4 2 Reasonably Foreseeable Misapplication 8 4 3 Personnel R...

Page 3: ...nts The user manual must be kept readily available in the immediate vicinity of the product 2 3 Local Safety and Accident Prevention Regulations The applicable local general safety and accident preven...

Page 4: ...ltage 12 V Current input ca 20 mA Sizes L x W x H 140 x 100 x 23 mm P11 Mini Burst Field Generator B P21 Mini Burst Field Generator E Short Description The P11 mini burst field generator creates a mag...

Page 5: ...ic 1 set may only be operated under supervision Damaged or defective devices must not be used The operating and safety instructions for all devices included in the measurement set up must be observed...

Page 6: ...surrounded by GND and deposited in the inner layer with GND Almost no magnetic field can reach around the signal line the assembly is much more resistant to interference Fig 5 Figure 3 Interference co...

Page 7: ...d waste Langer EMV Technik GmbH will remedy any fault due to defective material or defective manufacture during the statutory warranty period either by repair or by delivery of spare parts This warran...

Page 8: ...430093 0 49 0 351 430093 22 mail langer emv de www langer emv com For EMC measurements accompanying the development we offer Generators IC Measurement Technology Near Field Micro Probes Near Field Pr...

Reviews: