4.1  Intended Use

The EMC-Basic 1 set contains modules for demonstrating immunity and emission phenomena.

The EMC-Basic 1 set is powered by the supplied power supply.

4.2  Reasonably Foreseeable Misapplication

Incorrect application of the EMC-Basic 1 set may result in danger to the user, damage to the product 

and/or connected devices.

Examples of incorrect applications that can lead to danger:

- Safety devices are bypassed or disabled.

- The devices are not in a proper technical condition during operation.

- The EMC-Basic 1 set is not operated within the specified technical parameters.

- The scope of application is changed by modifying the design.

There are no claims due to misuse of the EMC-Basic 1 set!

4.3  Personnel Requirements

Only qualified personnel with knowledge and experience in the field of EMC are allowed to operate 

the EMC-Basic 1 set. 

4.4  Safety Instructions

If you use a Langer EMV-Technik GmbH product, please observe the following safety instructions to 

protect yourself against electric shock or the risk of injury.

–  Before each start-up, all connected devices must be checked externally for damage.

–  The EMC-Basic 1 set may only be operated under supervision.
–  Damaged or defective devices must not be used.
–  The operating and safety instructions for all devices included in the measurement set-up must be 

observed.

4. Safety

5.1  SF 11 - Demo Board B-Field Immunity

During immunity tests, interference pulses are often fed into the devices or assemblies to be tested 

via cables. This results in interference currents within the assemblies, which are always associated 

with magnetic fields (Fig. 1). Depending on the layout of the assembly, these fields can induce 

voltages in signal conductor loops and thus generate functional errors.

In order to find the causes of functional errors, it is important to determine where sensitive signal 

conductor loops are located on the module. The P11 pulser is used for this purpose.

It generates a small-scale magnetic field at its tip. This is used to simulate the magnetic field 

generated during an immunity test according to the standard in a very small area. To do this, the 

switched-on pulser is moved by hand over the assembly (Fig. 2). If there is a sensitive signal 

conductor loop below the pulse tip, the DUT generates the same functional fault as in the immunity 

test according to the standard.

5. Test Procedure

Figure 1: SF11 with interference current and magnetic field with two cables connected

Figure 2: P11 pulser is guided over the SF11 demo board

Summary of Contents for EMC-Basic 1 set

Page 1: ...1 www langer emv com User manual EMC Basic 1 set Demonstration Boards Mini Burst Field Generators www langer emv com EN 03 2022 V 1 0...

Page 2: ...5 2 4 Images 5 2 5 Limitations of Liability 5 2 6 Errors and Omissions 5 2 7 Copyright 5 3 Scope of Delivery 6 4 Safety 8 4 1 Intended Use 8 4 2 Reasonably Foreseeable Misapplication 8 4 3 Personnel R...

Page 3: ...nts The user manual must be kept readily available in the immediate vicinity of the product 2 3 Local Safety and Accident Prevention Regulations The applicable local general safety and accident preven...

Page 4: ...ltage 12 V Current input ca 20 mA Sizes L x W x H 140 x 100 x 23 mm P11 Mini Burst Field Generator B P21 Mini Burst Field Generator E Short Description The P11 mini burst field generator creates a mag...

Page 5: ...ic 1 set may only be operated under supervision Damaged or defective devices must not be used The operating and safety instructions for all devices included in the measurement set up must be observed...

Page 6: ...surrounded by GND and deposited in the inner layer with GND Almost no magnetic field can reach around the signal line the assembly is much more resistant to interference Fig 5 Figure 3 Interference co...

Page 7: ...d waste Langer EMV Technik GmbH will remedy any fault due to defective material or defective manufacture during the statutory warranty period either by repair or by delivery of spare parts This warran...

Page 8: ...430093 0 49 0 351 430093 22 mail langer emv de www langer emv com For EMC measurements accompanying the development we offer Generators IC Measurement Technology Near Field Micro Probes Near Field Pr...