2

INSTALLATION

RECEIVING THE MODEL SR-18 STOCK POT RANGE

Upon receipt, check for freight damage, both visible and concealed.  Visible damage should be
noted on the freight bill at the time of delivery and signed by the carrier's agent.  Concealed loss
or damage means loss or damage which does not become apparent until the merchandise has
been unpacked.  If concealed loss or damage is discovered upon unpacking, make a written
request for inspection by the carrier's agent within 15 days of delivery.  All packing material
should be kept for inspection.  Do not return damaged merchandise to Lang Manufacturing
Company.  File your claim with the carrier.

Uncrate your Stock Pot Range as near its intended location as practical.  The crating will help
protect the unit from the physical damage normally associated with moving it through hallways
and doorways.

VENTILATION AND CLEARANCES

The installation of any components such as vent hoods, grease extractors, or fire extinguisher
systems, must conform to their applicable nationally recognized installation standards.

 

Caution

    

  

Caution

 

Caution

   

 

Caution

Minimum clearance from combustible construction shall be:

3 inches from side walls

3 inches from back wall

DATA PLATE INFORMATION

Summary of Contents for SR-18-8T

Page 1: ...Lang Manufacturing Company 6500 Merrill Creek Parkway Everett WA 98203 Part Number 60802 17 Ph 425 349 2400 Fax 524 349 2733 January 1994 MODEL SR 18 8T Installation Operation Maintenance Manual ...

Page 2: ...g material should be kept for inspection Do not return damaged merchandise to Lang Manufacturing Company File your claim with the carrier Uncrate your Stock Pot Range as near its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways VENTILATION AND CLEARANCES The installation of any components...

Page 3: ...e rear of the control box The plug is a NEMA 50P The receptacle must be supplied by the installer and is a NEMA 6 50R Supply wire size must be large enough to carry the amperage load for the number of Stock Pot Ranges being installed The Stock Pot Range data plate is located on the side of the control box Wire size information can be found on the Stock Pot Range WARNING ELECTRICAL GROUNDING INSTRU...

Page 4: ...re Keep the Stock Pot Range either off or set at a moderate temperature 300 F when not being used This procedure saves energy keeps your kitchen cooler and extends the Stock Pot Range s useful life Boiling water is most quickly accomplished by 1 Starting with hot tap water 2 Covering stock pots with lids 3 Placing smaller stock pots 9 diameter or less either on right or left side of plate as the t...

Page 5: ...f the unit to gain access This also exposes the thermostat pilot lamps and terminal block The elements are clamped to the underside of the plate in the same fashion as other Lang griddles and hot tops In order to gain access to the elements four bolts holding the front and back guard rails to the body must be removed Pry the plate up and block in position Remove the element pan and zigzag by remov...

Page 6: ...6 PARTS LIST DESCRIPTION PART NUMBER Element 4000 Watt 11030 42 Pilot Lamp 31601 01 Knob Thermostat 70701 35 Terminal Block 30500 08 Thermostat 30402 23 ...

Page 7: ... safety valves gas and electric components found to be defective during the warranty period As to warranty service in the territory described above Lang will absorb labor and portal to portal transportation costs time mileage for the first 12 twelve months from the date of installation or eighteen 18 months from date of shipment from Lang Manufacturing which ever comes first IV This warranty does ...

Reviews: