background image

9

MAINTENANCE & CLEANING

CAUTION:

MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS
MEMBRANES AND CLOTHING.  PRECAUTIONS SHOULD BE TAKEN
TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND
PROTECTIVE CLOTHING.  CAREFULLY READ THE WARNING AND
FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE
USED.

CAUTION:

DO NOT USE YOUR HAND TO CHECK CHAR BROILER
TEMPERATURE.

NOTICE:

Service on this, or any other, LANG appliance must be performed by
qualified personnel only.  Consult your authorized service station
directory or call the factory at 1-800-224-LANG (5264), or
WWW.LANGWORLD.COM   For the service station nearest you.

CAUTION:

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED
BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE
BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE
EQUIPMENT AND WILL VOID ALL WARRANTIES.

CAUTION:

BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE
OPERATING INSTRUCTIONS, CAUTIONS AND SAFETY
INSTRUCTIONS CONTAINED IN THIS MANUAL.

CLEANING AND MAINTENANCE

 - Any piece of equipment works better and lasts longer

when maintained properly.  Cooking equipment is no exception.  Your char broiler must be kept
clean during the working day and thoroughly cleaned at the end of the day.

DAILY CLEANING:

Remove large pieces of food residue and carefully scrape spillovers from the drip tray below the
cooking surface.

Wash all exterior and interior surfaces with a hot soapy water solution.  DO NOT use harsh
abrasives on any portion of the stainless or painted surfaces.

Cast iron grates should be scraped with a wire brush frequently, and periodically soaked in a hot

water solution to remove grease from the pores of the cast iron.  NEVER expose the grate(s) to
extreme heat for the purpose of burning off excess grease.  This practice will shorten the useful life
of the grates.

PERIODIC CLEANING:

Check the ventilation system periodically to see that nothing has fallen down into the exhaust
vents.

A qualified service company should check your char broiler for safe and efficient operation at least
yearly.

STAINLESS STEEL:

 - All stainless steel body parts should be wiped regularly with hot soapy

water during the day and with a liquid cleaner designed for this material at the end of each day.
DO NOT USE steel wool, abrasive cloths, cleansers or powders to clean stainless surfaces.  If it is
necessary to scrape stainless steel to remove encrusted materials, soak in hot water to loosen the
material, then use a wood or nylon scraper.  DO NOT USE a metal knife, spatula, or any other
metal tool to scrape stainless steel! Scratches are almost impossible to remove.

Summary of Contents for LRB

Page 1: ...ompany 6500 Merrill Creek Parkway Everett WA 98203 Part Number 60801 Phone 425 349 2400 Fax 425 349 2733 Copyright 1999 WWW LANGWORLD COM Installation Operation Maintenance Troubleshooting Model LRB R...

Page 2: ...LLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM T...

Page 3: ...3 TABLE OF CONTENTS CHAPTER PAGE 1 READ FIRST 4 2 INSTALLATION 5 3 INITIAL START UP 8 4 MAINTENANCE CLEANING 9 5 PARTS LISTS 10 6 WARRANTY 12...

Page 4: ...to their applicable National State and locally recognized installation standards CAUTION ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS CAUTION KEEP FLOOR IN FRONT OF EQUIPME...

Page 5: ...h a gas pressure regulator packed with the unit All units are adjusted tested and inspected at the factory prior to shipment A manual gas shut off valve must be installed in the gas supply service lin...

Page 6: ...t Sealant on all pipe joints must be resistive to LP gas MANUAL SHUT OFF VALVE This installer supplied valve must be installed in the gas service line ahead of the appliance and regulator in the gas s...

Page 7: ...ition and a quick disconnect device that complies with the standard for quick disconnect devices for use with Gas Fuel ANSI Z21 41 and addendum Z21 41b or latest edition If disconnection of the restra...

Page 8: ...connections for leaks with a soapy water solution before lighting any pilots DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS Putting an open flame beside a new gas connection is extremely dangerous Befor...

Page 9: ...end of the day DAILY CLEANING Remove large pieces of food residue and carefully scrape spillovers from the drip tray below the cooking surface Wash all exterior and interior surfaces with a hot soapy...

Page 10: ...10 PARTS LIST...

Page 11: ...e Brass Natural Gas 91300 18 Burner Orifice Brass Propane Gas 91300 19 7 Burner Gas Valve Brass 91300 20 8 Adjustable double Pilot Valve Brass 91300 21 9 24 Valve Cover Stainless Steel 91300 22 30 Val...

Page 12: ...ing the warranty period As to warranty service in the territory described above Lang will absorb labor and portal to portal transportation costs time mileage for the first 12 twelve months from the da...

Reviews: