INSTALLATION

CAUTION:

UNIT IS EXTREMELY HEAVY.  FOR SAFE HANDLING, INSTALLER
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE
MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY,
OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND
MOVE IT TO THE PLACE OF INSTALLATION.

WARNING:

INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH PLUMBING.  IMPROPER INSTALLATION
CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO
EQUIPMENT.  UNIT MUST BE INSTALLED IN ACCORDANCE WITH
ALL APPLICABLE CODES.

CAUTION:

SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK
WHEN CUT.

NOTICE:

The data plate is located on the right side of the unit.  The Char broiler
gas specifications are on the data plate.  This information should be
carefully read and understood before proceeding with the installation.

WARNING:

BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO TEST
ALL JOINTS FOR GAS LEAKS.

NOTICE:

The installation of any components such as a vent hood, grease
extractors, fire extinguisher systems, must conform to their applicable
National, State and locally recognized installation standards.

2.1  General

All Lang Char broilers are shipped with a gas pressure regulator packed with the unit.  All units
are adjusted, tested, and inspected at the factory prior to shipment.

A manual gas shut-off valve must be installed in the gas supply (service) line ahead of the char
broiler and gas pressure regulator for safety and ease of future service.

The gas pressure regulator supplied must be installed on the appliance prior to connecting the
equipment to the gas line.  Failure to install a regulator will void the equipment warranty and
result in a potentially hazardous condition.

The appliance and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 PSI.

The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSI.

2.2 Installation

RATING PLATE

 - Information on  this plate includes the model and serial numbers.  When

communicating with factory about a unit or requesting special parts or information, this data is
essential for proper identification.  Other information on this plate is the BTU/hr input of the
burners, operating gas pressure in inches WC, and whether the unit is orificed for natural or
propane gas.

Summary of Contents for LRB

Page 1: ...ompany 6500 Merrill Creek Parkway Everett WA 98203 Part Number 60801 Phone 425 349 2400 Fax 425 349 2733 Copyright 1999 WWW LANGWORLD COM Installation Operation Maintenance Troubleshooting Model LRB R...

Page 2: ...LLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM T...

Page 3: ...3 TABLE OF CONTENTS CHAPTER PAGE 1 READ FIRST 4 2 INSTALLATION 5 3 INITIAL START UP 8 4 MAINTENANCE CLEANING 9 5 PARTS LISTS 10 6 WARRANTY 12...

Page 4: ...to their applicable National State and locally recognized installation standards CAUTION ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS CAUTION KEEP FLOOR IN FRONT OF EQUIPME...

Page 5: ...h a gas pressure regulator packed with the unit All units are adjusted tested and inspected at the factory prior to shipment A manual gas shut off valve must be installed in the gas supply service lin...

Page 6: ...t Sealant on all pipe joints must be resistive to LP gas MANUAL SHUT OFF VALVE This installer supplied valve must be installed in the gas service line ahead of the appliance and regulator in the gas s...

Page 7: ...ition and a quick disconnect device that complies with the standard for quick disconnect devices for use with Gas Fuel ANSI Z21 41 and addendum Z21 41b or latest edition If disconnection of the restra...

Page 8: ...connections for leaks with a soapy water solution before lighting any pilots DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS Putting an open flame beside a new gas connection is extremely dangerous Befor...

Page 9: ...end of the day DAILY CLEANING Remove large pieces of food residue and carefully scrape spillovers from the drip tray below the cooking surface Wash all exterior and interior surfaces with a hot soapy...

Page 10: ...10 PARTS LIST...

Page 11: ...e Brass Natural Gas 91300 18 Burner Orifice Brass Propane Gas 91300 19 7 Burner Gas Valve Brass 91300 20 8 Adjustable double Pilot Valve Brass 91300 21 9 24 Valve Cover Stainless Steel 91300 22 30 Val...

Page 12: ...ing the warranty period As to warranty service in the territory described above Lang will absorb labor and portal to portal transportation costs time mileage for the first 12 twelve months from the da...

Reviews: