INITIAL START-UP

CAUTION:

ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM
COMBUSTIBLE MATERIALS.

CAUTION:

KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY.  IF SPILLS
OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS
OR FALLS.

INITIAL PILOT LIGHTING

All Lang char broilers are adjusted and tested before leaving the factory, effectively matching them
to sea level conditions.  Adjustments and calibrations to assure proper operation may be necessary
on installation to meet local conditions, low gas characteristics, to correct possible problems caused
by rough handling or vibration during shipment, and are to be performed only by qualified service
personnel.  These adjustments are the responsibility of the customer and/or dealer and are not
covered by our warranty.

Check all gas connections for leaks with a soapy water solution before lighting any pilots.  

DO

NOT USE AN OPEN FLAME TO CHECK FOR LEAKS.

  Putting an open flame beside a new

gas connection is extremely dangerous.

Before lighting any pilots, make sure that burner valves and thermostats are turned "off".

Broiler pilots can be accessed through the openings in the front cover panel in the case of counter
or floor mounted units.  Pilot flame adjustments for all units can be accomplished through the use
of the adjusting screw(s) found at the front of the unit.

FINAL PREPARATION

TOP SECTION

 - New units are wiped clean with solvents at the factory to remove any visible

signs of dirt, oil, or grease remaining from the thin film of nontoxic rust protectant.  Food
preparation surfaces should be washed thoroughly with hot, soapy water before being used.

The top grates should be removed and washed before use.  With these removed, it will be possible
to remove any plastic tie cords holding the burners in place.

Summary of Contents for LRB

Page 1: ...ompany 6500 Merrill Creek Parkway Everett WA 98203 Part Number 60801 Phone 425 349 2400 Fax 425 349 2733 Copyright 1999 WWW LANGWORLD COM Installation Operation Maintenance Troubleshooting Model LRB R...

Page 2: ...LLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM T...

Page 3: ...3 TABLE OF CONTENTS CHAPTER PAGE 1 READ FIRST 4 2 INSTALLATION 5 3 INITIAL START UP 8 4 MAINTENANCE CLEANING 9 5 PARTS LISTS 10 6 WARRANTY 12...

Page 4: ...to their applicable National State and locally recognized installation standards CAUTION ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS CAUTION KEEP FLOOR IN FRONT OF EQUIPME...

Page 5: ...h a gas pressure regulator packed with the unit All units are adjusted tested and inspected at the factory prior to shipment A manual gas shut off valve must be installed in the gas supply service lin...

Page 6: ...t Sealant on all pipe joints must be resistive to LP gas MANUAL SHUT OFF VALVE This installer supplied valve must be installed in the gas service line ahead of the appliance and regulator in the gas s...

Page 7: ...ition and a quick disconnect device that complies with the standard for quick disconnect devices for use with Gas Fuel ANSI Z21 41 and addendum Z21 41b or latest edition If disconnection of the restra...

Page 8: ...connections for leaks with a soapy water solution before lighting any pilots DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS Putting an open flame beside a new gas connection is extremely dangerous Befor...

Page 9: ...end of the day DAILY CLEANING Remove large pieces of food residue and carefully scrape spillovers from the drip tray below the cooking surface Wash all exterior and interior surfaces with a hot soapy...

Page 10: ...10 PARTS LIST...

Page 11: ...e Brass Natural Gas 91300 18 Burner Orifice Brass Propane Gas 91300 19 7 Burner Gas Valve Brass 91300 20 8 Adjustable double Pilot Valve Brass 91300 21 9 24 Valve Cover Stainless Steel 91300 22 30 Val...

Page 12: ...ing the warranty period As to warranty service in the territory described above Lang will absorb labor and portal to portal transportation costs time mileage for the first 12 twelve months from the da...

Reviews: