Correct manifold pressures are:
Griddle:
5 inches water column for
natural gas.
10 inches water column for
propane.
Broiler:
3 1/2 inches water column for
natural gas.
6 inches water column for
propane.
When replacing the plug in the manifold, a use a pipe joint compound or sealant that is resistant to the
action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable to Lang Manufacturing
Company.
WARNING
BEFORE LIGHTING, USE A SOAP AND WATER SOLUTION TO TEST ALL JOINTS FOR GAS
LEAKS
After the griddle is in its final position, adjust the legs so the griddle
body
is level back to front. This will
allow the grease to run into the grease gutter and provide the proper combustion air for the burners.
This appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any testing of that system at test pressures in excess of 1/2 PSIG (3.45 kPA) and the appliance must
be isolated from the gas supply piping system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.45 kPA).
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING) PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED 3-PRONG RECEPTACLE.
DO NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE PLUG.
SPECIFICATIONS
Construction Specifications
Model
Number
Overall Griddle
Surface
Square
Inches Of
Griddle
Surface
Number
Of Griddle
Controls
Number of
Griddle
Burners
Number
Of Grease
Drawers
Clearance From Combustible
Surfaces
Shipping
Weight
Width
Depth
Sides
Back
Bottom
(Required)
GGB24-TI
24 Inches
23 Inches
552
2
2
1
5 Inches
14 Inches
4 Inches
250
GGB36-TI
36 Inches
24 Inches
828
3
3
1
5 Inches
14 Inches
4 Inches
460
GGB48-TI
48 Inches
25 Inches
1104
3
4
1
5 Inches
14 Inches
4 Inches
600
Gas And Electrical Requirements
Model
Number
Total BTU
Output
Gas
Connection(s)
Gas Pressures In
Inches Of Water
Maximum
Delivery
Pressure
Electrical Connection
Cord/Plug &
Pressure
Regulator
Natural
Propane
Voltage
Amps
GGB24-TI
89,000
One 3/4" NPT
5
10
1/2 LB
115
3.5
Supplied
GGB36-TI
116,000
One 3/4" NPT
5
10
1/2 LB
115
3.5
Supplied
GGB48-TI
143,000
One 3/4" NPT
5
10
1/2 LB
115
3.5
Supplied
Summary of Contents for GGB-24