BROILER
Trouble
Possible Cause
Ignitor not sparking
Failed spark controller
Failed tilt switch
Failed air switch
Failed combustion blower
Failed transformer
Failed safety thermostat
Failed spark electrode
Spark but not ignition
Failed spark controller
Failed gas solenoid valve
Broiler gas valve turned off
Incorrectly adjusted air shutter
Plugged orifice
Broiler turns off after extended use
Incorrectly adjusted sense electrode
Incorrectly adjusted air shutter
Failed safety thermostat
Plugged burner tiles
Taking too long to light
Incorrectly adjusted spark electrode
Incorrectly adjusted air shutter
Plugged enrichment orifice
Plugged burner tiles
Hazy blue flame on tile face
Incorrectly adjusted air shutter
Leak in air path to burner face
Incorrectly adjusted gas regulator
Not hot enough
Incorrectly adjusted gas regulator
Plugged main burner ofifice
Plugged burner tiles
Broiler not turning off
Failed flame switch
Failed spark controller
Failed gas solenoid valve