7
PHASING RANGE ASSEMBLY
Follow the drawings, below, to group the supply wires to match the power phase.
THREE PHASE
SINGLE PHASE
LOAD REQUIREMENTS
For proper supply wire and circuit breaker size, refer to the chart below.
THREE PHASE LOADING
NOMINAL AMPS PER LINE
THREE PHASE
SINGLE
PHASE
K.W. PER PHASE
208 VOLT
240 VOLT
480 VOLT
Star
Model
Number
Lang
Model
Number
L1 - L2
L2 -L3
L3 -L1
Total
KW
Conn
L1 L2 L3 L1 L2 L3 L1 L2 L3
208V 240V
136SB 36S
6.0
10.0
5.0
21.0 45.8 66.7 62.5
39.7 57.8 54.2
19.9 28.9 27.1
101.0 87.5
N/A
72S
#1
6.0
10.0
5.0
21.0 45.8 66.7 62.5
39.7 57.8 54.2
19.9 28.9 27.1
101.0 87.5
N/A
72S
#2
6.0
10.0
5.0
21.0 45.8 66.7 62.5
39.7 57.8 54.2
19.9 28.9 27.1
101.0 87.5
R36C RF21S
6.6
10.0
5.0
21.6 48.3 69.2 62.5
41.9 59.9 54.2
20.9 30.0 27.1
103.8 90.0
N/A
RF42S#1
6.6
10.0
5.0
21.6 48.3 69.2 62.5
41.9 59.9 54.2
20.9 30.0 27.1
103.8 90.0
N/A
RF42S#2
6.6
10.0
5.0
21.6 48.3 69.2 62.5
41.9 59.9 54.2
20.9 30.0 27.1
103.8 90.0
TOP ONLY
5.0
5.0
5.0
15.0 41.7 41.7 41.7
36.1 36.1 36.1
18.1 18.1 18.1
72.1 62.5