Lang DO36 Installation & Operation Manual Download Page 6

 

ELECTRICAL CONNECTION 

DANGER 

MAKE SURE THE POWER SUPPLY TO THE APPLIANCE IS TURNED OFF BEFORE MAKING 
THE CONNECTION. 

If the oven is to be assembled as a range, skip this section and refer to the 
Range Top Installation Manual. 

The electrical connection is made through 
a 1 1/4 inch knockout in the bottom of the 
oven to a terminal block located behind an 
access door that is below the control 
panel. 

Before connecting the oven to power 
check the data plate located behind the 
access door to confirm that the power 
supply wires are large enough to carry the 
load. 

A one deck oven requires a single phase 
connection only; however, this does not 
mean the oven cannot be connected to a 
three phase service, simply use two lines 
of the three phase. 

INTERCONNECTING THE OVENS 

If the oven is assembled as a 2 deck 
model, remove the wire from one of the 
Stacking Kit envelopes and cut it in half.  

Strip the cut ends of the wires 3/4 inch 
and install them into the terminal block of 
the top oven.  Snap a 3/4 inch plastic 
bushing from one of the Stacking Kit 
envelopes into the hole in the bottom of 
the top oven and run the wires from the 
top oven through it to the terminal block in 
the bottom oven.  Connect the top oven 
wires into the terminal block with the wires 
from the bottom oven.  Refer to the wiring 
diagram in this manual for the correct 
phasing of the wires. 

If the oven is assembled as a 3 deck 
model, remove the wires from all three 
Stacking Kit envelopes and cut one in 
half.  Use the 2 full length wires to connect 
to the top deck and the cut wire to connect 
to the middle deck.  Refer to the figure 
below or the wiring diagram in back of this 
manual for the correct wire grouping at the 
bottom oven terminal block. 

Summary of Contents for DO36

Page 1: ...national 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W475 Ph 314 678 6315 Fax 314 781 2714 Rev A www langworld com November 2 2007 Installation Operation and Maintenance Instructions Deck Ov...

Page 2: ...ENTS 5 RANGE ASSEMBLY 6 INSTALLATION ON OVEN BASE 6 ELECTRICAL CONNECTION 6 PHASING RANGE ASSEMBLY 7 LOAD REQUIREMENTS 7 OPERATION INITIAL START UP 8 NORMAL OPERATION 8 PREHEATING 8 OVEN RACK 8 CONTRO...

Page 3: ...be placed on the pebble oven deck or raised off of the deck and placed in the middle of the cavity on a rack supplied with the oven The heating elements are located above the product and below the ov...

Page 4: ...to combustible surfaces must be maintained 4 inches to sides 3 inches to back Make sure the wire leads that supply electricity to the cook top or upper oven decks are not pinched between the oven and...

Page 5: ...the legs are packaged in with the range top If the oven is to be stacked on another oven the legs are packaged in a separate box marked Fabricated Legs Place some cardboard on the floor and gently tip...

Page 6: ...THE OVENS If the oven is assembled as a 2 deck model remove the wire from one of the Stacking Kit envelopes and cut it in half Strip the cut ends of the wires 3 4 inch and install them into the termi...

Page 7: ...VOLT 240 VOLT 480 VOLT SINGLE PHASE AMPS MODEL NO LI L2 L2 L3 L3 L1 TOTA L Kw L1 L2 L3 L1 L2 L3 L1 L2 L3 208V 240V DO36I 6 0 0 6 28 8 28 8 0 25 25 0 12 5 12 5 0 28 8 25 DO36L 6 0 0 6 28 8 28 8 0 25 25...

Page 8: ...range top and remove the 2 X 4 Allow the range top to set into place so that the pins in the bottom if the range top nest into the holes in the top of the oven base ELECTRICAL CONNECTION The electrica...

Page 9: ...3 L1 L2 L3 208V 240V 136SB 36S 6 0 10 0 5 0 21 0 45 8 66 7 62 5 39 7 57 8 54 2 19 9 28 9 27 1 101 0 87 5 N A 72S 1 6 0 10 0 5 0 21 0 45 8 66 7 62 5 39 7 57 8 54 2 19 9 28 9 27 1 101 0 87 5 N A 72S 2 6...

Page 10: ...ading the product To compensate for the temperature loss during loading set the oven thermostat 50 degrees over the desired cooking temperature load the oven then reset the thermostat to the proper te...

Page 11: ...shed with the top 3 Heat switch set to the Low position and the bottom 3 Heat switch set to either Medium or High The following Temperature Switch Setting and Rack Position chart is suggested as a gui...

Page 12: ...cts with high moisture content open the vent by pulling the knob out The moisture will be vented out the back of the oven as steam If the products require a moist baking environment push the vent damp...

Page 13: ...hanical devices Thermostat calibration should be attempted only when continued experience indicates inaccurate cooking temperatures and then only after the calibration of the thermostat has been thoro...

Page 14: ...n screw Insert a small flat blade screwdriver down the thermostat shaft until it contacts the screw Grasp the thermostat shaft so it does not move while turning the calibration screw Use caution when...

Page 15: ...ot Internal Circuit Breakers off Ovens Not Interconnected Improper Phasing at Terminal Block Reset Breakers Connect all Decks to Lower Terminal Block Correct Phasing Circuit Breakers Trip Supply and O...

Page 16: ...12 0 18 0 L1 L2 L2 L3 L3 L1 THREE PHASE AMPS 208 VOLT 240 VOLT 45 8 28 8 50 0 50 0 L1 50 0 28 8 28 8 66 7 L2 50 0 28 8 0 0 62 5 L3 43 3 43 3 25 0 39 7 L1 43 3 25 0 25 0 57 8 L2 43 3 25 0 0 0 54 2 L3 S...

Page 17: ...12 0 18 0 L1 L2 L2 L3 L3 L1 AMPS 480 VOLT 19 9 12 5 21 7 21 7 L1 21 7 12 5 12 5 28 9 L2 21 7 12 5 0 0 27 1 L3 L1 L2 L3 4 3 3 2 L2 L3 C 2 1 L1 L2 1 2 L1 C L2 5 TERMINAL BLOCK 1ST DECK 1 OVEN WIRING 2N...

Page 18: ...SK2423 Rev 6 08 09 Model DO36 Deck Oven LA36 Deck Oven 2 1 3 5 6 7 1 9 1 10 11 12 13 14 15 16 8 4 See Detail A See Detail B...

Page 19: ...8KW DO36 380VM 4 2N 11050 26 2 ELE 36OVN 240V I S 1 2KW DO36 240VM 2N 11050 30 ELMNT 36 OVEN 480V I S DO36 440VM DO36 480V CLDO36L 440V 2N 11050 32 ELE 36 OVN 208V I S 1 2KW DO36 208VM 2N 11050 34 EL...

Page 20: ...Model DO36 Deck Oven Details A B LA36 Deck Oven Details A B SK2424 Rev A 6 09 2010 33 1 3 5 12 11 13 14 15 16 17 18 20 21 23 24 25 28 29 30 7 31 32 27 26 19 7 6 8 7 9 10 4 2 Detail A Detail B...

Page 21: ...SSYEMBLY 550 F BLACK Y9 70701 12 2 KNOB ASSYEMBLY 550 F RED 12 Q9 70701 09 1 KNOB ASSY MANUAL TIMER 13 2J 31601 01 1 PILOT LT 250V 6LEAD BLK DO36 208VM 2J 31601 02 PILOT LT 480V 6LEAD BLK DO36 480V DO...

Page 22: ......

Page 23: ......

Page 24: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: