background image

 

6

 

INSTALLATION 

DANGER 

THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.  
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN 
ELECTROCUTION AND DEATH.

 

 

WARNING 

INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED 
TO WORK WITH ELECTRICITY.  IMPROPER INSTALLATION CAN CAUSE 
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.  UNIT MUST 
BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.

 

 

NOTICE 

The data plate is located behind the access cover to the right of the oven 
door.  The range voltage, wattage, serial number, wire size, and clearance 
specifications are on the data plate.  This information should be carefully 
read and understood before proceeding with the installation.

 

 

NOTICE 

The installation of any components such as a vent hood, grease extractors 
and fire extinguisher systems must conform to their applicable National, 
State and locally recognized installation standards.

 

 

Electrical Connection 

Electrical connection can be hooked into the bottom front, below the terminal 
block, or at the right back of the unit behind the terminal block. 

 

Range Voltage 

The Lang Model CLCN36-H-S can be operated on 440 Volts.  

 
 
 
 

 

 

 

Summary of Contents for CLCN36-H-S

Page 1: ...rrill Creek Parkway Everett WA 98203 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 2000 Installation Operation Maintenance Troubleshooting Model CLCN36 H S Electric Cruise Line Hot T...

Page 2: ...UGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT DANGER POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH WARNING POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD...

Page 3: ...F CONTENTS TOPIC PAGE TABLE OF CONTENTS 3 IMPORTANT INSTRUCITIONS 4 UNPACKING 5 INSTALLATION 6 INITIAL START UP 7 OPERATION 7 CLEANING 8 TROUBLESHOOTING 9 PARTS LISTS 10 EXPLODED VIEWS 11 12 WIRING DI...

Page 4: ...re extinguisher systems must conform to their applicable National State and locally recognized installation standards CAUTION ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS CA...

Page 5: ...g move the range as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un crati...

Page 6: ...ht of the oven door The range voltage wattage serial number wire size and clearance specifications are on the data plate This information should be carefully read and understood before proceeding with...

Page 7: ...rvation and Manufacturing oils may be burning off as smoke This is normal and not cause for alarm OPERATION CAUTION ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM COMBUSTIBLE MATERIALS CAUTION TO A...

Page 8: ...E USED After Meal Cleaning Empty the grease drawer often or whenever it is 3 4 full Remove the grease drawer after each meal and wash the inside and outside of the drawer Keep the hot top surface clea...

Page 9: ...ion nearest you Tests If an item on the list is followed by an asterisk the work should be done by a factory authorized service representative Possible Cause Test Product is not cooked enough No test...

Page 10: ...CLB 531 1 6 T stat 850 30302 23 7 Knob 70701 28 8 2 Pole Contactor 125 Amp 30500 11 9 Element Plate Spacer CLR 514 10 Element Plate Support CLR 512 11 Element Plate CLR 511 12 Outer Element 440 Volt...

Page 11: ...11 EXPLODED VIEW...

Page 12: ...12 EXPLODED VIEW Cont d...

Page 13: ...13 WIRING DIAGRAM...

Page 14: ...14 NOTES...