background image

®

Viking Range Corporation

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information, call 1-888-VIKING1 (845-4641)

or visit the Viking Website at vikingrange.com

F20934 EN

(032212)

Freestanding 30” Gas

Self-Clean Sealed Burner Range

Installation

Summary of Contents for RDSCG230-5B

Page 1: ...nt Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Website at vikingrange com F20934 EN 032212 Freestanding 30 Gas Self Clean Sealed Burner Range Installation ...

Page 2: ... how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING CAUTION Warnings Important Safety Instructions_____________________________________________________3 Dimensions __________________________________________________________________________________6 Specifications _______________________________________________________________________________...

Page 3: ...h can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed operated and maintained in accordance to the instructions in this document WARNING TIPPING HAZARD To reduce the risk of property damage or personal inj...

Page 4: ...0 0 0 cm To top of backguard add 6 15 2 cm To top of high shelf add 18 3 16 46 2 cm Gas Requirements Shipped standard for Natural gas field convert with LP conversion kit included with each unit accepts standard residential 1 2 1 3 cm ID gas service line Gas Manifold Pressure Natural 5 0 W C P Liquid Propane L P 10 0 W C P Electrical Requirements 120VAC 60 Hz 4 ft 121 9 cm 3 wire cord with grounde...

Page 5: ...y result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood 66 min 167 6 cm to 72 max 182 9 cm 66 min 167 6 cm to 72 max 182 9 cm 24 61 0 cm or 27 38 6 cm 30 76 2 cm 6 15 2 cm Wood Composite Overlay Wood Composite Overlay 30 min ...

Page 6: ...tuate with local demand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked with a manometer natural gas requires 5 0 W C P and LP gas requires 10 0 W C P Incoming line pressure upstream from the regulator must be 1 W C P higher than the manifold pressure in...

Page 7: ... may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed NOTICE DO NOT use the handle or oven door to lift the oven Remove door before installation to ensure that it is not used to lift ...

Page 8: ... and internal mounting hardware 3 Screw legs into couplings on all four corners Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit with metal shims only as the adjustment required may exceed the thread available in the leg 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 4 Move unit into opening Leveling Adjustments Alignment Ins...

Page 9: ...ays check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING TIPPING HAZARD To reduce the risk of property damage or personal injury install anti tipping device provided in accordance with the installation instructions in this document Device must be engaged properly to prevent...

Page 10: ...e trim screws Door Replacement and Adjustment 1 2 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 3 Burner heads and burner caps are packed in the cardboard top pack with the grates Align burner head on burner base Place burner cap on burner head Place grate onto the burner pan Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repea...

Page 11: ...tions should remain with the unit for future reference Service Registration Performance Checklist A qualified installer should carry out the following checks h Check top burner ignition See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake burner on full power h Check convection fan function convection fan comes on when put in Convection...

Page 12: ..._______________________________________________________________________________________________________ Notes ________________________________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________________...

Reviews: