11
Maintenance & Cleaning Cont’d
Thermostat Bulb Check
The two thermostat bulbs, (temperature control thermostat bulb and over-temp
thermostat bulb), are all connected to the fryer heating elements. The brackets that
hold these bulbs in place should be checked on a regular basis for tightness. If any
of the brackets/bulbs become loose, the brackets that hold the bulbs should be
tightened right away.
Component Access
All maintenance may be done from the front. Opening the front by removing 4 bolts
gains access to all circuitry, with the exception of the thermostat, which is located
on the top where the thermostat knob is located. To gain access to the safety
thermostat, the thermostat, and element terminals remove the 4 screws from the
front of the access cover located above and to the rear of the oil well.