INSTALLATION

Electrical Connection

The griddle is supplied with a cord and plug.  The receptacle is not provided with the griddle. 
Follow the receptacle manufacturer’s instructions when connecting the receptacle to the power supply.

Gas Connection

This griddle is manufactured for use with the type of gas indicted on the nameplate.  

 

Contact the factory if your type of gas does not match the nameplate data.
All gas connectors must be in accordance with local codes and comply with the National Fuel Federal 

Gas Codes ANSI Z223.1 latest edition.
This appliance should be installed with a separate gas valve in the gas line ahead of the unit. Use a 

3/4 inch or larger gas supply line.

Remove

 the 5/16 inch nuts securing the rear of burners.  These nuts are for securing the main burners 

during transportation only.  The rear burner shield must be removed to gain access to the nuts.
A pressure regulator for the type of gas specified is supplied with each appliance.

This regulator must be installed in the gas supply line.

  (Note the direction of the gas flow arrow.)  

The pressure in the manifold of the appliance should be tested with a manometer and the regulator 

adjusted for proper pressure with the appliance operating at full fire.  A 1/8 inch NPT tap is provided in 

the manifold for connecting a manometer.
Correct manifold pressures are:

 

5 inches water column for natural gas

 

10 inches water column for propane

When replacing the plug in the manifold, a pipe joint compound or sealant should be used that is 

resistant to the action of liquid petroleum gas.
Initial adjustments are the responsibility of the installer and are not chargeable to Star Manufacturing 

International.
After the griddle is in its final position, adjust the legs to create 1/8 inch slant from back to front.  

This will allow the grease to run into the grease gutter and provide the proper combustion air for the 

burners.

DANGER:  THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL 

PROVIDED.  FAILURE TO GROUND THE APPLIANCE COULD 

RESULT IN ELECTROCUTION AND DEATH.

 

INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL 

QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING.  

IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL 

AND/OR DAMAGE TO EQUIPMENT.  UNIT MUST BE INSTALLED IN 

ACCORDANCE WITH ALL APPLICABLE CODES.

NOTICE: 

The data plate is located inside the control compartment of each 

griddle. The griddle voltage, serial number, gas specifications, and 

clearance specifications are on the data plate.  This information 

should be carefully read and understood before proceeding with 

the installation.

NOTICE: 

The installation of any components such as a vent hood, grease 

extractors, fire extinguisher systems, must conform to their 

applicable National, State and locally recognized installation 

standards.

WARNING

Summary of Contents for 224T

Page 1: ...IL2466 ACCU TEMP Spark Ignition GAS GRIDDLE Commercial 224T 236T 248T 260T 272T Installation and Operation Instructions 2M W358 Rev I 3 03 15 236T...

Page 2: ...ON MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT WARNING RISK OF FIRE OR ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE CON...

Page 3: ...13 Burner Air Shutter Adjustment 13 Troubleshooting Symptoms Possible Causes 14 Possible Causes Test 15 Wiring Diagram 16 Exploded View Parts List 18 28 PROBLEMS QUESTIONS or CONCERNS Before you proc...

Page 4: ...Actual Shipping 224T 16 4 x 24 1 x 30 4 243 lbs 280 lbs 65 418mm x 613mm x 773mm 110 kg 127 kg 236T 16 4 x 36 1 x 30 4 368 lbs 420 lbs 418mm x 917mm x 773mm 167 kg 191 kg 248T 16 4 x 48 1 x 30 4 Sides...

Page 5: ...NAT X 5 WC 224T NATLR X 5 WC 224TR NAT X 5 WC 236TCHG NAT X 5 WC 81 000 BTU hr 236TC LPTE X 10 WC 236TC NAT X 5 WC 236TCHE NAT X 5 WC 236THE NAT X 5 WC 236THE NATCD X 5 WC 236THG LP X 10 WC 236THG NAT...

Page 6: ...twelve inch section of the griddle is controlled independently Technical Griddle operates on either Natural gas or Propane This must be specified when ordering It is shipped with a Power Cord and Plu...

Page 7: ...THE UNIT IS EXTREMELY HEAVY FOR SAFE HANDLING INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT SUCH AS A FORKLIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM...

Page 8: ...ed in the manifold for connecting a manometer Correct manifold pressures are 5 inches water column for natural gas 10 inches water column for propane When replacing the plug in the manifold a pipe joi...

Page 9: ...the main toggle switch to STANDBY Seasoning the Griddle Plate non chrome only Set the temperature dials to 300 F 148 C Observe the burners through the opening at the top of the control panel When the...

Page 10: ...ND DRY IF SPILLS OCCUR CLEAN IMMEDIATELY TO AVOID THE DANGER OF SLIPS OR FALLS CAUTION SUGGESTED TIMES AND TEMPERATURES PRODUCTS TEMPERATURE F C TIME MIN HAMBURGER 350 F 176 C 2 patties per LB 6 to 8...

Page 11: ...ature SEQUENCE OF OPERATION Power On When the griddle is connected to 115 Volt power the spark module for each section starts sparking While they are sparking the solenoid valve for the pilot burners...

Page 12: ...that the chrome surface has been misused or abused or subjected to the following situations 1 Improperly installed 2 Incorrect voltage applied to Chrome units allowing the surface to overheat and dis...

Page 13: ...Y READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED NOTICE Never leave a chlorine sanitizer in contact with stainless steel surfaces longer than 10 minutes Longer conta...

Page 14: ...test to identify test procedures SYMPTON POSSIBLE CAUSE Entire griddle not lighting Failed regulator or plugged regulator vent Failed transformer Power indicator is not lit No power to cord outlet Gr...

Page 15: ...AN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES CAUTION WARNING POSSIBLE CAUSE TEST Failed regulator Replace regulator Failed thermostat Check for corre...

Page 16: ...L D D I R G S A G 6 3 P M E T U C C A D W 7 0 0 2 9 1 2 1 4 3 W 2 2 1 1 6 M 2 5 1 0 x x x D E T O N S S E L N U E C N A R E L O T S E L G N A 1 L T N I G F M R A T S O T L A I T N E D I F N O C N O I...

Page 17: ...OCK PAIR REQUIRED FOR NOTES 1 2 3 4 4 7 5 5 7 8 8 10 11 9 4 7 5 8 DJS 10 23 2007 W D ACCUTEMP 3 GAS GRIDDLE WITH CSE12 CLAMSHELL 2M 61122 W24 CK 1 2 3 UP DOWN C B A R W BLU W 9 3 5 6 4 16 15 10 10 10...

Page 18: ...Rev A 7 19 13 Model 224T thru 272T GAS ACCU TEMP GRIDDLE 1 3 2 4 5 6 7 8 9 10 11 13 15 14 16 17 18 23 29 Correctional Package 24 25 28 26 27 19 21 22 20 12 Electrical Conduit Units mfg before July 20...

Page 19: ...43 1 SWITCH GUARD 17 2I 05 07 0013 1 BOOT SWITCH 18 Y9 31601 07 1 1 PILOT LT 28V W TIN CLIP 19 2C 20101 77 4 SCRW MS PLT 6 32 X 25 20 Y9 70701 19 Black Y9 70701 19 2 Red 2 KNOB PLATE ASSY 450 D 21 2R...

Page 20: ...03 2 SHIELDMNT EZG STD W XLH12 FRONT GUTTER K9 EZGR 371 SHIELD MOUNT EZGR REAR GUTTER 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 4 FOOT 4 DIE CAST 14 2T 30402 27 3 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06...

Page 21: ...1 13 2 SHIELDEND EZG STD W XLH12 11 K9 EZG 371 03 2 SHIELDMNT EZG STD W XLH12 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 4 FOOT 4 DIE CAST 14 2T 30402 27 4 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06 1 SWT TOG...

Page 22: ...11 K9 EZG 371 03 2 SHIELDMNT EZG STD W XLH12 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 4 FOOT 4 DIE CAST 14 2T 30402 27 5 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06 1 SWT TOG ON ON DPDT BLK 16 Z1 70 07 0343...

Page 23: ...DMNT EZG STD W XLH12 12 K9 EZG 625 2 S S SIDE 13 2A Z0314 6 FOOT 4 DIE CAST 14 2T 30402 27 6 STAT ADJ 450 DEG 48 PILOT 15 2E 30303 06 1 SWT TOG ON ON DPDT BLK 16 Z1 70 07 0343 1 SWITCH GUARD 17 2I 05...

Page 24: ...LOT TUBE 9 4 2K 70101 07 BRAS TBE TEE 1 4CC 5 2C 20102 04 SCRW PHD ST 8 32X 5 PLTD 6 2E 31400 07 XFORMR120 208 240 24V40VA 7 2J 80300 03 SPRK IGNITR MODULE SM2 9 2E 30501 03 TERM STRP 4 POLE W PUSH 10...

Page 25: ...PT 10 2K 70101 124 FITTING 1 8NPT X 3 8COMP 11 2V 6671 VALVE LINCOLN BRASS 3817 12 2C 20102 08 SCRW PHD ST 8 32X 375 13 K9 EZG W297 BRKT SOLENOID VALVE 14 2C 20102 04 SCRW PHD ST 8 32X 5 PLTD 15 PS 60...

Page 26: ......

Page 27: ......

Page 28: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: