2M-W358;
ACCU-TEMP
Spark Ignition Gas Griddle
2M-W358;
ACCU-TEMP
Spark Ignition Gas Griddle
13
MAINTENANCE & CLEANING continued
Burner Air Shutter Adjustment
• The air shutters are pre-set at the factory.
However, minor adjustments may be required in
the field to accommodate differences in gas and
elevation.
• To adjust the air shutters, loosen the set screw
holding the air damper to the burner near the gas
inlet.
• Adjust the air mixture until the burner flame just
flickers on the burner. “Lift-off” or yellow flame
indicates improper shutter adjustment.
• Periodically inspect and clean the air shutters to
insure complete combustion.
WARNING:
KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY
OR HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC.
CAUTION:
MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS
MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN
TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND
PROTECTIVE CLOTHING. CAREFULLY READ THE WARNING AND
FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO
BE USED.
NOTICE: Never leave a chlorine sanitizer in contact with stainless steel
surfaces longer than 10 minutes. Longer contact can cause
corrosion.
Calibration
• Set the temperature dials to 350°F (176°C).
• Allow the burners to cycle ON and OFF at least five times before attempting to calibrate.
• Place a surface thermometer in the center of each cooking section to be calibrated.
• Allow the burners to cycle several times while recording the temperature at which the burners turn
ON and OFF.
• Average the temperatures together, if the average temperature is within 10° of the set temperature,
the thermostat is within specifications and needs no adjustment.
• If the thermostat is out of specification, remove the thermostat knob and inset a small flat blade
screw driver down the stem of the thermostat and turn the adjusting screw at the base of the stem.
• Turning the screw counter-clockwise raises the griddle temperature while clockwise lowers the
temperature.
CAUTION
WARNING
Set Screw
Air Shutter
Burner
IL1578