Installation
Receiving the Fryer
Upon receipt, check for freight damage, both visible and concealed.Visible damage
should be noted on the freight bill at the time of delivery and signed by the carrier's
agent. Concealed loss or damage means loss or damage, which does not become
apparent until the merchandise has been unpacked.
If concealed loss or damage is discovered upon unpacking, make a written request for
inspection by the carrier's agent within 15 days of delivery. All packing material should
be kept for inspection.
Do not return damaged merchandise to Star Manufacturing Company.File your claim
with the carrier.
Prior to un-crating, move the fryer as near its intended location as practical. The crating
will help protect the unit from the physical damage normally associated with moving it
through hallways and doorways.
Electrical Connection
Check the data plate located inside the drain valve door for fryer electrical rating. Check
power source to insure that it is the correct voltage and current rating.
Electrical service may be made through a standard 1¼-inch conduit. A hole is provided
through the rear pane
l.
A knockout is also provided in the bottom rear of the fryer, so that power may be brought
in from below the unit. Connect power cord to 3-Pole terminal block, refer to wiring
diagram.
Plug the hole on the rear panel when using bottom power entry.
Check the National Electrical Code for fuse or circuit breaker requirements.
A two pole terminal block is provided behind the rear access cover for connection to an
external fire control system if required. A jumper is provided across these terminals
when the fryer leaves the factory. The jumper on this terminal block is in series with the
contactor coil circuits. If connection to a fire control system is required, remove this
jumper and supply a relay contact closure to maintain this closed circuit. If the fire
control system does not have this type output, a separate relay must be provided to
interface the system. Use copper wire only.
PHASING
CAUTION:
DO NOT APPLY POWER TO THESE TERMINAL.
EXTERNAL POWER WILL DAMAGE THE FRYER
CONTROL CIRCUITRY.
Connect a ground lead to the green ground lug provided in the rear
compartment.These fryers are to be connected to three-phase power as follows:
Connect wires 1 and 4 to line 1, wires 2 and 5 to line 2, and wires 3 and 6 to line 3.
Please refer to wiring diagram for correct single/three-phase connections, if problems
occur please contact factory.
CAUTION:
DO NOT CONNECT TO A CIRCUIT OPERATING
AT MORE THAN 150 VOLTS TO GROUND.