Maintenance
Maintenance of the C-28 series fryers is simple and straightforward. A bulb thermostat
located near the right heating element as the fryer is viewed from the front provides
temperature control. This thermostat controls the No. 1 contactor. The over temperature
thermostat located next to the left heating element provides protection in case of malfunction
of the temperature control. It will open both contactors removing all power from the heating
elements.
A circuit diagram of the fryer is located on the rear cover of the control box. This box may be
removed by removing the four sheet metal screws located beneath the box on the left and right
sides of the fryer lower front.
In the event the fryer is built into a location, all maintenance may be done from the front by
removing the oil pot to gain access to the contactors. To remove the pot, the control box must be
removed as above. Also, remove the small section of sheet metal baffle held on by two sheet
metal screws, located just above the drain valve. The front of the pot may now be lifted up and
moved forward until the rear of the pot will rotate up and out. The baffles behind the pot may be
removed by taking out four screws. This exposes the contactors.
The thermostats are located in the head assembly. The bottom cover of the head is removable
for access to the elements, thermostats and pilot lamps.
In 480-volt units, a transformer is provided in the rear of the fryer to step 480 volts to 240 volts for
operation of the control circuit.
Summary of Contents for 130f
Page 10: ...WIRE DIAGRAMS 208 240 VOLT...
Page 11: ...WIRE DIAGRAMS 480...