background image

Laney

6

Laney

The ENHANCE control provides an increased definition at the

low-end of the frequency spectrum giving you a tighter,

punchier sound. The ENHANCE control does this by providing

a dip in the frequency-response of the amplifier at

approximately 200hz.

This dip eliminates some of the

secondary-harmonics of the important low-frequencies around

40-80 Hz producing a thicker sound.

Turning the control

through to its maximum has the effect of boosting both the

low and high-frequency content of the signal whilst not

effecting the mids.

Selects the LO MID-frequencies to be cut or boosted in

conjunction with the

LO PARAMID LEVEL control (7). To

access

low LO mid-frequencies turn the FREQUENCY control

anticlockwise, to access higher LO MID frequencies turn the

FREQUENCY control clockwise
Sets the level of boost or cut applied to the frequency set by

control (6).

For frequency-boost turn the control

clockwise.

For frequency-cut, turn the control anti-

clockwise
Hi Paramid Frequency : Selects the HI MID-frequencies to

be cut or boosted in conjunction with the Hi PARAMID LEVEL

control (9). To access

low Hi mid-frequencies turn the

FREQUENCY control anticlockwise, to access higher Hi MID

frequencies turn the FREQUENCY control clockwise
Sets the level of boost or cut applied to the frequency set by

control 8. For frequency-boost turn the control clockwise.

For frequency-cut, turn the control anti-clockwise
Controls the high-frequency response of the pre-amplifier.
Allows the on-board limiter to be defeated if desired. With

the switch in the out position the limiter is engaged. The

limiter is automatically triggered at high-output levels

and is designed to prevent power-amp distortion at high-

output levels. When the limiter is autpmatically triggered

an LED lights up to indicate the limiter is active. It is

possible to have the limiter engaged but not have the LED

active.

The LIMITER monitors both power-amp clipping and

load so it automatically registers the cabinet-impedance and

sets itself accordingly.
Sets the overall listening level of the amplifier.
Switches the on-board horn either on or off.
XLR socket for direct-injection of the amplifier signal to a

mixing-desk or additional power-amplifier. The XLR socket

provides a balanced low-impedance output-signal.

Controls the low-frequency response of the pre-amplifier

4.Enhance:

5.Bass:

8. Hi Paramid frq:

9.Lo Paramid Level:

10.Treble:

11.Limiter:

12. Volume:

13.Horn switch:

14.D.I:

6. Lo Paramid frq:

7.Lo Paramid Level:

Richter

Summary of Contents for Richter R1

Page 1: ...Laney R1 R2 R3 R3H R4 R4H R5 User manual Richter Bass Amplification...

Page 2: ...liquids are not spilled into the unit through any ventilation holes or openings On no account place drinks on the unit 15 A qualified service technician should check the unit if The power cord has be...

Page 3: ...from your new amplifier it is important you take time to read this user manual and to familiarise yourself with the control functions and facilities available INTRODUCTION This manual has been written...

Page 4: ...This dip eliminates some of the secondary harmonics of the important low frequencies around 40 80 Hz producing a thicker sound Turning the control through to its maximum has the effect of boosting bo...

Page 5: ...ARA ID ACTIVE POWER ACTIVE TunerOut FXReturn FXSend Designed And Assembled in the UK by BLT Industries LTD M P C 240 W 50 60 H AXIMUM OWER ONSUMPTION ATTS Z W ARNING T HIS EQUIPMENT MUST BE EARTHED W...

Page 6: ...s to be cut or boosted in conjunction with the PARAMID GAIN control 7 To access LO mid frequencies turn the FREQUENCY control anticlockwise to access HI mid frequencies turn the FREQUENCY control cloc...

Page 7: ...K DO NOT OPEN TunerOut FXReturn FXSend Extension Loudspeaker S N ERIAL UMBER 8 M I R U M F L C OHM INIMUM MPEDANCE EFER TO SER ANUAL OR OUDSPEAKER ONNECTIONS R3 Rear R3 R3H Front LIMITER HORN VOLUME D...

Page 8: ...ENCY control anticlockwise to access higher Hi MID frequencies turn the FREQUENCY control clockwise Sets the level of boost or cut applied to the frequency set by control 8 For frequency boost turn th...

Page 9: ...AUTION T N R O REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS O USER SERVICEABLE PARTS INSIDE EFER SERVICING TO QUALIFIED PERSONNEL ONLY A TTENTION R EMPLACER LE FUSIBLE SEULEMENT PAR LE MEME...

Page 10: ...t As a general rule avoid extreme settings of the sliders try to set the GRAPHIC with as little cut or boost as possible Controls the high frequency response of the pre amplifier Allows the on board L...

Page 11: ...MEME CALIBRE ATTENTION S E REFERER AU MANUEL D UTILISATION POUR LA CONNECTION HAUT PARLEURS R5 Front 17 15 R5 Rear Normal and High inputs are provided for connection of bass guitars High output basses...

Page 12: ...nt power amp distortion at high output levels When the limiter is autpmatically triggered an LED lights up to indicate the limiter is active It is possible to have the limiter engaged but not have the...

Page 13: ...165W 300W 300W 300W 120W 240W 300W 300W 450W 450W 450W 1M Ohm 1M Ohm 1M Ohm 1M Ohm 1M Ohm 1M Ohm 1M Ohm 20 40mV 10 20mV 12 24mV 12 24mV 12 24mV 12 24mV 12 24mV 700mV 800mV 800mV 800mV 800mV 800mV 800m...

Page 14: ......

Page 15: ......

Page 16: ...fication Newlyn Road Cradley Heath West Midlands B64 6BE United Kingdom WWW laney co uk In the interest of on going product development Laney reserves the right to amend specifications without prior n...

Reviews: