R E M E D Y I N G F A U L T S
Filter life not sufficient
Cause of fault
Remedy
Pressure maintaining valve settings not correct
Adjust as prescribed
Filter cartridge unsuitable
Replace by a prescribed filter cartridge type
Filter cartridge too old
Observe expiration date
Filter cartridge packaging incorrect / damaged /
already opened. Filter cartridge already partly
saturated before change
Store filter cartridges properly, dispose defective
cartridges
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Operating temperature too high
Ensure sufficient ventilation
Oil consumption too high
Cause of fault
Remedy
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Compressor oil unsuitable
Use prescribed oil quality
Operating temperature too high
Observe prescribed operating temperatures
Oil leak at the compressor block
Tighten corresponding mounting screws, if
necessary replace corresponding paper sealing /
o-ring / shaft seal