R E M E D Y I N G F A U L T S
Final pressure can not be reached
Strong compressor vibration
Cause of fault
Remedy
V-belt tension too loose
Tension V-belt
Drive motor / Compressor unit loosely
Retighten mounting screws
Anti vibration mounts used up
Replace
Ground not levelled
Ensure a solid and level ground
Cause of fault
Remedy
Connections leaky
Retighten or clean/replace if necessary
Final pressure safety valve leaky
Replace
Pipes / heat exchanger broken
Replace
Condensate drain valves leaky
Unscrew valves, check sealing surfaces, clean,
replace if necessary
Final pressure switch stop unit
Verify settings, replace if necessary
Piston of pneumatic condensate valve sticks
Clean pneumatic condensate valve and restore
function, check/replace o-rings, replace valve
completely if necessary
Air supply too low
Cause of fault
Remedy
Inlet and outlet valves contaminated / defective Clean, replace if necessary
Cylinder(s), piston(s) or piston ring(s) used up
Replace
V-belt slips
Tension V-belt
See chapter "Final pressure can not be reached" See chapter "Final pressure can not be reached"
Summary of Contents for SC-300 E
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 300 E LW SC 350 E Version 12 22 E...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...E A T T A C H M E N T Version 11 12 E...
Page 79: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 87: ...ANNEX...