Seite A - 22
A
LW SC-180 ES / LW SC-250 ES
Version: 09.12.2022
I N S T A L L A T I O N
Electrical Installation
For installation of electrical equipment, observe the following:
• If control devices are delivered by the factory, refer to the appropriate wiring diagram.
• Ensure correct installation of protective conductors.
• Check conformity of motor and control device tension and frequency with those of the electric
network (see name plate on the compressor).
• The fusing should be done in accordance with the valid regulations of the responsible electricity
supply company.
• When connecting the unit to the electrical supply, check the compressor direction of rotation
(see chapter "Maintenance" -> Check turning direction).
• Fuse the motor correctly (see table; use slow-blow fuses).
Warning
Work on the electrical equipment on / with the machine / unit may only be carried out by
qualified electricians.
!
No.
Designation
1.
Circuit diagram number
2.
Compressor type
3.
Power supply
4.
Frequency
5.
Motor current consumption
6.
Nominal motor power
Fig. Compressor name plate
2.
1.
3.
4.
5.
6.
Summary of Contents for SC-180 ES
Page 3: ...A Operating Instructions Breathing Air Compressor LW SC 180 ES LW SC 250 ES Version 12 2022...
Page 12: ...A S I C H E R H E I T S H I N W E I S E...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 65: ...A M A I N T E N A N C E R E C O R D S...
Page 73: ...E A T T A C H M E N T Version 11 12 E...
Page 77: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 85: ...ANNEX...