STEP
17
:
WIRE
POWER
MODULE
1.
20
inches
of
wire
must
extend
out
top
of
pedestal
to
ensure
that
power
module
will
assemble
into
and
out
of
pedestal
body.
The
required
gauge
wire
for
connecting
to
terminal
blocks
is
10
or
12
AWG.
All
terminal
block
screws
must
be
torqued
to
20
inch
‐
pounds.
Customer
supplied
15
or
20
amp
devices
must
be
Weather
Resistant
UL
listed
GFCIs.
USB
devices
must
be
UL
listed.
WIRING
DIAGRAM:
2
GANG,
2
GFCI
RECEPTACLES
GROUND
BAR
5
POLE
TERMINAL
BLOCK
SWITCH/LED
GFCI
MODULE
GFCI
MODULE
INCOMING
WIRE
FROM
SERVICE
GROUND
INCOMING
WIRE
FROM
SERVICE
LINE
INCOMING
WIRE
FROM
SERVICE
NEUTRAL
WIRING
DIAGRAM:
2
GANG,
1
GFCI
RECEPTACLE,
1
USB
MODULE
GROUND
BAR
2
POLE
TERMINAL
BLOCK
SWITCH/LED
GFCI
MODULE
USB
MODULE
INCOMING
WIRE
FROM
SERVICE
GROUND
INCOMING
WIRE
FROM
SERVICE
LINE
INCOMING
WIRE
FROM
SERVICE
NEUTRAL