background image

Included

 

components

Tools

 

Required

Safety

 

glasses

Wrenches,

 

1/2”,

 

9/16”

Socket

 

wrench,

 

7/16”

Screwdrivers,

 

Phillips

 

and

 

straight

 

blade

Wiring

 

tools

 

and

 

connectors

Level

Grease

Landscape

 

Forms

 

is

 

not

 

responsible

 

for

 

site

 

preparation

 

and

 

footings.

  

Refer

 

to

 

the

 

installation

 

guide

 

for

 

the

 

Outdoor

 

Power

 

anchor

 

kit

 

for

 

installing

 

the

 

anchor

 

bolts.

IMPORTANT!

Please

 

read

 

all

 

instructions

 

before

 

beginning

 

installation.

Legrand

 

Electrical

 

systems

 

conform

 

to

 

and

 

should

 

be

 

properly

 

grounded

 

in

 

compliance

 

with

 

requirements

 

of

 

the

 

current

 

National

 

Electrical

 

Code

 

or

 

codes

 

administered

 

by

 

local

 

authorities.

All

 

electrical

 

products

 

may

 

present

 

a

 

possible

 

shock

 

or

 

fire

 

hazard

 

if

 

improperly

 

installed

 

or

 

used.

 

Legrand

 

electrical

 

products

 

may

 

bear

 

the

 

mark

 

of

 

a

 

nationally

 

Recognized

 

Testing

 

Laboratory

 

and

 

should

 

be

 

installed

 

in

 

conformance

 

with

 

current

 

local

 

and/or

 

the

 

National

 

Electrical

 

Code.

ASSEMBLE

 

WITH

 

CARE!

To

 

protect

 

this

 

finish

 

during

 

assembly,

 

place

 

unwrapped

 

powder

 

coated

 

parts

 

on

 

packaging

 

foam

 

or

 

other

 

non

marring

 

surface.

  

Do

 

not

 

place

 

or

 

slide

 

powder

 

coated

 

parts

 

on

 

concrete

 

or

 

other

 

hard

 

or

 

textured

 

surface

 

– this

 

will

 

damage

 

the

 

finish

 

causing

 

rust

 

to

 

occur.

  

Use

 

touch

up

 

paint

 

on

 

any

 

gouges

 

in

 

the

 

finish

 

caused

 

by

 

assembly

 

tools.

Installation Guide

Outdoor Power

Power Pedestal and Outdoor Charging Station with Accent Light

www.landscapeforms.com      Ph: 800.521.2546

Date: June 10, 2016

Page 1 of 8

4X

 

– Rubber

 

cap

Power

 

Pedestal

1X

 

– Wire

 

Nut

1X

 

– Warning

 

Label

Charging

 

station

 

with

 

accent

 

light

Summary of Contents for Outdoor Power

Page 1: ...k or fire hazard if improperly installed or used Legrand electrical products may bear the mark of a nationally Recognized Testing Laboratory and should be installed in conformance with current local and or the National Electrical Code ASSEMBLE WITH CARE To protect this finish during assembly place unwrapped powder coated parts on packaging foam or other non marring surface Do not place or slide po...

Page 2: ...ep 6 Remove top cap and gasket Step 5 Remove top four screws metal washers and rubber washers Screws are 10 32 x 3 4 Outdoor Power Power Pedestal and Outdoor Charging Station with Accent Light Date June 10 2016 Step 8 Remove two nuts 7 16 SOCKET Step 4 Remove the template from the cement pour and replace with mounting bracket Level the mounting bracket 9 16 WRENCH Step 7 Disconnect LED light plug ...

Page 3: ... Step 16 Pull wires through extrusion and attach pedestal to mounting bracket Step 15 Splice ground wire on mounting bracket to incoming ground wire using supplied weather proof wire nut Outdoor Power Power Pedestal and Outdoor Charging Station with Accent Light Date June 10 2016 Step 11 Remove four screws and carefully pull power module out from pedestal body Step 10 Loosen screw inside pedestal ...

Page 4: ...rminal block screws must be torqued to 20 inch pounds Customer supplied 15 or 20 amp devices must be Weather Resistant UL listed GFCIs USB devices must be UL listed WIRING DIAGRAM 2 GANG 2 GFCI RECEPTACLES GROUND BAR 5 POLE TERMINAL BLOCK SWITCH LED GFCI MODULE GFCI MODULE INCOMING WIRE FROM SERVICE GROUND INCOMING WIRE FROM SERVICE LINE INCOMING WIRE FROM SERVICE NEUTRAL WIRING DIAGRAM 2 GANG 1 G...

Page 5: ...UND BAR 2 POLE TERMINAL BLOCK SWITCH LED USB MODULE USB MODULE INCOMING WIRE FROM SERVICE GROUND INCOMING WIRE FROM SERVICE LINE INCOMING WIRE FROM SERVICE NEUTRAL WIRING DIAGRAM 3 GANG 2 GFCI RECEPTACLES 1 USB MODULE GROUND BAR 5 POLE TERMINAL BLOCK SWITCH LED GFCI MODULE GFCI MODULE INCOMING WIRE FROM SERVICE GROUND INCOMING WIRE FROM SERVICE LINE INCOMING WIRE FROM SERVICE NEUTRAL USB MODULE GR...

Page 6: ...3 GANG 1 GFCI RECEPTACLE 2 USB MODULES GROUND GROUND BAR 2 POLE TERMINAL BLOCK SWITCH LED USB MODULE GFCI MODULE INCOMING WIRE FROM SERVICE GROUND INCOMING WIRE FROM SERVICE LINE INCOMING WIRE FROM SERVICE NEUTRAL USB MODULE LIGHTING CIRCUIT SCHEMATICS LED ARRAY 5 POLE TERMINAL BLOCK CONNECTOR INCOMING WIRE FROM LIGHTING LINE INCOMING WIRE FROM LIGHTING NEUTRAL LED LIGHT DRIVER ...

Page 7: ...ing sure that wires are not pinched during assembly Screws should be tight using a screwdriver Step 18 Assemble LED driver front plate back onto power module Step 19 Apply grease to four protrusions on door then slide door back onto power module Step 22 Route driver wire through grommet in lens assembly Place top portion of pedestal lens and lower gasket onto pedestal body Make sure gasket is plac...

Page 8: ...nderside of pedestal top cap Step 26 Place top cap and gasket onto top of pedestal Make sure gasket is flat between the pedestal components Top cap is directional and only fits on pedestal one way Step 28 Assemble four caps into mating holes on pedestal top Push caps into pedestal top until they are flush with top surface Step 27 Assemble top four screws metal washers and rubber washers Screws sho...