13
Start Up
STEP
ACTION
1
Select the proper
L&R
Cleaning Solution.
2
Dilute with warm tap water as specified and
fill one half to two-thirds of the tank.
3
Add parts to be cleaned. Use a basket or
other accessory which keeps material off the
bottom of the tank. If necessary, add more
solution to bring the level to about 1 inch
from the top of the tank.
4
Plug the cleaner’s line cord into a grounded
outlet.
5
To activate your machine, simply set your
timer (on mechanical timers turn knob
clockwise) to the number of minutes desired
for cleaning. These self-timing units will
automatically shut themselves off at the end
of the cycle.
For recessed installations with an optional
remote timer… connect the machine’s power
cord to the outlet on the rear of the remote
timer and connect the remote timer’s power
cord to a grounded outlet. Set the machine’s
timer to the “HOLD” position. Then set the
timer on the remote to the number of
minutes desired for cleaning.
NOTE: If this is the first time you are running the cleaner or you
have changed the cleaning solution, you must degas the
solution. Fresh solutions contain many dissolved gasses which
reduce effective ultrasonic action. Although solutions will
naturally degas over time, operating the machine for five to ten
minutes before using it to clean will accelerate the degas
process.