Specifications - Ultrasonic Cleaning System  

 
*    Note Heated Tanks are 50/60 Hz 

** Tank to be located in a dry location, 0-35°C, RH 96% Non-Condensing non-corrosive 

atmosphere below 2000 M altitude. 

***  Do Not position equipment so that it is difficult to operate the disconnecting device. 
**** Disconnect unit from mains by unplugging the line cord. 

 

1.0 

    

Introduction 

 

1.1

  Your Ultrasonic Cleaning System is easy to operate and install. 

Optimum cleaning results will result if certain guidelines are adhered to: 

 

   

1.1.1

   Keep solution level high. 

 

1.1.2

   Keep water/soap ratio adequate. 

 

1.1.3

   Rinse out tank when "sludge" covers tank bottom. 

 

1.1.4

   Read and observe Operation Warnings and Cautions (Section 5.0). 

 

1.2

 

Please call for information, suggestions or if you have any concerns. 

 

1.3

 

Please read the entire manual before using system. 

MODEL 

NUMBER 

OVERALL 

SIZE 

TANK 

SIZE 

WEIGHT 

SONIC 

POWER

 

Heat 

Watts 

Heater 

Line 

Frequency

 

Heater 

Volts

 

HEATER 

Fuse

 

401206 

(HEATED) 

19” x 15” x 14” 

12” x 6” x 8” 

32 4.1w/in

2

 590 

50/60Hz 

117 
230

 

T15.0A/117V 
T10.0A/230V 

4005 

14” x 12” x 14” 

12” x 10” x 10” 

46 5w/in

2

 N/A 

 

N/A N/A 

4105 

(HEATED) 

14” x 12” x 14” 

12” x 10” x 10” 

46 5w/in

2

 450 

50/60Hz 

117 

230 

T15.0A/117V 
T10.0A/230V 

4010 

16” x 12” x 16” 

16” x 12” x 12” 

77 5w/in

2

 N/A 

 

N/A N/A 

4110 

(HEATED) 

16” x 12” x 16” 

16” x 12” x 12” 

77 5w/in

2

 900 

50/60Hz 

117 
230 

T20.0A/117v 

T15.0A/230V 

4022 

22” x 18” x 20” 

20” x 16” x 16” 

101 3.8w/in

2

 N/A 

 

N/A N/A 

4122 

(HEATED) 

22” x 18” x 20” 

20” x 16” x 16” 

101 3.8w/in

2

 2000 

50/60Hz 

117 
230 

T30.0A / 117v 

T20.0A/230V 

4042 

26” x 22” x 20” 

24” x 20” x 20” 

170 3.8w/in

2

 N/A 

 

N/A N/A 

4142 

(HEATED) 

26” x 22” x 20” 

24” x 20” x 20” 

170 3.8w/in

2

 4000 

50/60Hz 

230 only 

T30.0/230V 

SS6530 

19264

 

31” x 17” x 11” 

30” x 12” x 6” 

75 1.7w/in

2

 1000 

50/60Hz 

 

117 

 

 

T15.0A/117V 

 

Summary of Contents for 4000 Series

Page 1: ...1 L R Model 4000 Series Ultrasonic Cleaning System Operator s Manual L R Manufacturing Company 577 Elm Street Kearny NJ 07032 3604 Phone 201 991 5330 Fax 201 991 5870 CN 85001 Rev E ...

Page 2: ...allation Instructions 4 0 Operation Instructions 5 0 Operation Warnings Cautions 6 0 Interconnection Wiring Diagram 7 0 Warranty and Records WARNING If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired ...

Page 3: ...ncerns 1 3 Please read the entire manual before using system MODEL NUMBER OVERALL SIZE TANK SIZE WEIGHT SONIC POWER Heat Watts Heater Line Frequency Heater Volts HEATER Fuse 401206 HEATED 19 x 15 x 14 12 x 6 x 8 32 4 1w in2 590 W 50 60Hz 117 230 T15 0A 117V T10 0A 230V 4005 14 x 12 x 14 12 x 10 x 10 46 5w in2 N A N A N A 4105 HEATED 14 x 12 x 14 12 x 10 x 10 46 5w in2 450 W 50 60Hz 117 230 T15 0A ...

Page 4: ...ug making sure that they are reasonably tight Use Teflon pipe thread sealer when replacing plug or cap 3 3 Fill tank with recommended L R solutions or equivalent to approximately two inches from the top edge of tank Note that solution displacement when submerging part to be cleaned must be taken into consideration 3 4 Make sure that the generator s Power switch is off 3 5 See Section 6 0 for Inter...

Page 5: ...tor to proper 50 60 Hz socket with third wire ground 5 9 Always turn unit off when not in use 5 10 Keep tank covered with supplied tank cover 5 11 Avoid placing hands in the machine 5 12 Service must be done by competent personnel only 5 13 Be sure to unplug the machine before moving it 5 14 Do not subject your machine to shock impact 5 15 Do not immerse machine in water or any other liquid 5 16 D...

Page 6: ... POWER RECEPTACLE TO PROPER GROUNDED SECOND CONNECT EACH A C POWER CORD WITH A C POWER CABLES DISCONNECTED TO BNC CONNECTOR AT REAR OF GENERATOR FIRST CONNECT TANK ULTRASONIC POWER CABLE A C CONNECTOR 40KHZ GENERATOR TANK INTERCONNECTION WIRING DIAGRAM ...

Page 7: ... of one year from the date of purchase to be free of defects in material and workmanship Machine will be repaired free of charge to the customer during the warranty period This warranty does not include damage or product failure resulting from misuse abuse or transportation damage Operating the machine dry is the most common misuse which results in failure ...

Page 8: ...ISION HISTORY C N 85001 REVISION ECN DESCRIPTION APPROVED DATE C 8294 SEE ECN J P M 01 22 2007 D 8316 REVISED SHEET 3 SEE ECN 8316 J P M 01 24 2007 E 8725 REVISED SHEET 3 2000 M WAS 2000 Ft J P M 11 17 2010 ...

Reviews: