4-10 HYDRAULIC LEVELER ADJUSTMENT
If a unit is equipped with an optional hydraulic
leveler, adjust to the following dimensions for most
field conditions.
4-10.1
Lower the disc to the ground to remove
the load on the leveler assembly.
4-10.2
Remove the level indicator rod from the
leveler tube
(See Figure 4-12)
.
4-10.3
Loosen the 1-1/2-6 hex lock nut at the
rear of the leveler tube (an adjustment
wrench is provided for this).
4-10.4
Screw the leveler tube out to approxi-
mately 6-1/2" for 23' and 26' models, 7" for
29' models, and 7-1/2" for 33' models.
4-10.5
Install the level indicator rod in the lev-
eler tube and level indicator gauge.
4-11
7430hydlevel 1
LEVELER SCREW
ASSEMBLY
4 X 30
FOLD CYLINDER
1-1/2-6 HEX
LOCK NUT
LEVELER
TUBE
LEVEL INDICATOR
GAUGE
LEVEL
INDICATOR ROD
6-1/2” THREADS (23’ AND 26’ MODELS)
7” THREADS (29’ MODEL)
7-1/2” THREADS (33’ MODEL)
Figure 4-12 Hydraulic Leveler Adjustment