TROUBLESHOOTING GUIDE
5-3
WINGS FOLD TOO FAST
RESTRICTORS NOT PROPERLY
INSTALLED
BLACK RESTRICTOR FITTINGS
SHOULD BE IN BOTH ENDS OF
FOLD CYLINDERS
TILT CYLINDER DOES NOT FULLY
EXTEND AFTER LOWERING
MACHINE INTO WORKING POSITION
CIRCUIT CONTROLS IN THE
TRACTOR ARE NOT PROPERLY SET
UP
CONSULT THE OPERATORS MANUAL
FOR THE TRACTOR. INCREASE
TIMER SETTING TO FULLY
STROKE THE TILT CYLINDER
WING TIP OPERATING SHALLOW
WING FOLD CYLINDER NOT FULLY
EXTENDED
FULLY EXTEND WING FOLD
CYLINDERS WHILE UNFOLDING
THE HSL
WING FOLD CYLINDER LEAKING
INTERNALLY
REPAIR OR REPLACE THE WING
FOLD CYLINDER
TRACTOR VALVE LEAKING
CONNECT CIRCUIT TO A DIFFERENT
TRACTOR SET OF QUICK
COUPLERS TO CONFIRM
GAUGE POINT CYLINDERS DO NOT
FULLY EXTEND
GAUGE POINT CYLINDERS NOT
SYNCHRONIZED
SYNCHRONIZE CYLINDERS BY
HOLDING HYDRAUILC CIRCUIT IN
EXTEND POSITION FOR 5 TO 10
SECONDS AFTER FULL
EXTENSION
GAUGE POINT CYLINDERS NOT
INSTALLED IN PROPER SERIES
INSTALL CYLINDER IN DECREASING
DIAMETERS AS DISTANCE FROM
CENTER INCREASES
HOSES NOT PROPERLY
CONNECTED
CHECK HOSE ROUTINGS AGAINST
SCHEMATICS
MACHINE WILL NOT UNFOLD (RAISE
WING FRAMES OUT OF TRANSPORT
SADDLES)
TRACTOR VALVE NOT WORKING
TRY A DIFFERENT TRACTOR
CIRCUIT KNOWN TO WORK
LIMIT VALVE ON HITCH SAFETY
CIRCUIT NOT CLOSING BY-PASS
CIRCUIT
•
CONFIRM SPRING PLUNGER TO
BE DEPRESSING LIMIT VALVE
PLUNGER WHEN FOLDED
FORWARD
•
HITCH SAFETY CIRCUIT LIMIT
VALVE LEAKING
MACHINE WILL NOT TILT (REAR
UPWARD) OR FOLD
TRACTOR VALVE NOT WORKING
TRY A DIFFERENT TRACTOR
CIRCUIT KNOWN TO WORK
CHECK VALVE ON HITCH SAFETY
CIRCUIT NOT CLOSING, LEAKING
•
CLEAN CHECK VALVE
•
REPLACE CHECK VALVE
MACHINE WILL NOT FOLD OR
UNFOLD (WITH WING FRAMES OUT
OF TRANSPORT SADDLES)
TRACTOR VALVE NOT WORKING
TRY A DIFFERENT TRACTOR
CIRCUIT KNOWN TO WORK
HOSES NOT PROPERLY
CONNECTED
CHECK HOSE ROUTINGS AGAINST
SCHEMATICS
HYDRAULIC DEPTH CONTROL LIMIT
VALVE NOT WORKING
HYDRAULIC HOSES NOT PROPERLY
CONNECTED
CHECK HOSE ROUTINGS AGAINST
SCHEMATICS
DEPTH STOP CONTACTS LIMIT
VALVE BUT DOES NOT CLOSE OFF
FLOW
•
CLEAN LIMIT VALVE
•
REPLACE LIMIT VALVE
MACHINE WILL RAISE BUT NOT
LOWER
CHECK LIMIT VALVE AND MANIFOLD
FOR CORRECT PLUMBING
WHEEL BEARING FAILURE
SEALS NOT PROPERLY INSTALLED
TRIPLE LIP SEALS SHOULD BE
INSTALLED WITH LIPS POINTING
OUTWARD AWAY FROM THE HUB
PROBLEM
PROBABLE CAUSE
SOLUTION
Summary of Contents for 7831
Page 2: ......
Page 4: ......
Page 12: ...2 4 F 801 1115 Edition STANDARD SPECIFICATIONS Table provided for general use NOTES...
Page 30: ...4 14 F 801 1115 Edition OPERATION AND MAINTENANCE Table provided for general use NOTES...
Page 34: ...5 4 F 801 1115 Edition TROUBLESHOOTING GUIDE Table provided for general use NOTES...
Page 35: ......