TROUBLE SHOOTING
MOTOR STOPS WITH SWITCH ON
CAUTION!
TURN SWITCH OFF IMMEDIATELY
1.
Too much equipment operated on same circuit on which Landis
machine is connected. Check circuit breaker or fuse box.
2.
Refer to the lockout procedures before the next step (page 4)
.
3.
An overload may have caused the thermal overload protector in
motor to shut off current. Be sure sander is off, then find and
eliminate cause for overload.
Some motors are equipped with manual Re-Set thermal overload
protector wait at least 30 minutes, then firmly press Re-Set button
on motor with eraser end of pencil or a small blunt dowel. After
approximately 30 minutes you should be able to hear or feel
overload protector click in when pushed to reset. After Re-Set
clicks in, turn the main switch ON and start (Stop/Start switch) the
machine.
After this procedure, the motor should run normally. If the motor
has no Re-Set button, wait 30 minutes that the engine would shrink.
After this time, the engine should reset itself.
If you believe that the motor presents an anomaly, please contact
Landis customer service at 1 800 634-0806.