G130 Installation and Commissioning  

                      July 2012 ver 01 

© 2012 Gyr Ltd 

 

Installation Procedure 

 

The G130 meter measures the volume of gas passed through it and 
is certified for use up to 6 m

3

/hr.  

The meter is intended for a closed environment with the meter in a 
suitable cabinet and is intended for use in a mechanical environment 
M1 and an electromagnetic environment E1. 

The meter is intended for installation in a residential environment by 
suitably qualified personnel. 

3.1 

General 

Installation of the gas meter shall be in accordance with the requirements of The Gas 
Safety (Installation and Use) Regulations 1998 and only by suitably qualified personnel. 
 
The procedure includes fitting the gas meter to the pipe bosses, opening the valve for 
operation (if necessary), ensuring the system is leaktight and purging the pipes of air.   
 
Access to the installation and commissioning function is achieved through the Service 
Menu (see section 4) 
 
The G130 Smart Gas meter requires no maintenance by the end user.  The external 
surfaces may be cleaned, if required, using a damp or anti-static cloth. 

 

3.2 

The safe removal of the existing meter.  

1. Isolate the gas supply via the Emergency control valve or other locally defined 
methodology.  

2. Record any necessary details, such as outgoing meter serial number and the outgoing 
meter volume index.  

3. Store outgoing meter for return to stores or disposal, as required.  

3.3 

The safe connection of the G130 Smart gas meter  

1. Connect the gas meter to the gas installation having first ensured that the connection 
seals are in a suitable condition.  

2. Confirm the installation is leak tight via the locally approved methodology.  

3. Ensure that the air within the installation / new meter is safely purged. If the G130 
Smart Ready gas meter is supplied with the valve closed the open valve procedure 
should be used to open the valve to enable the flow of gas.  

 

3.4 

G130 Meter displays 

The G130 display is normally blank.  Pressing either of the two buttons on the front 
panel will wake the meter.   

The default display is the Meter Index.   

Press button A again to display the valve status screen. The two options are shown 
below.   

Summary of Contents for E6V

Page 1: ...L G Confidential G130 Installation and Commissioning Manual July 2012 ver 01 2012 Landis Gyr Ltd Advanced Metering Infrastructure L G Electronic Smart Ready Gasmeter G130 Installation Manual ...

Page 2: ...d Revision history Issue Date Comments 1 July 2012 First revision of G130 Installation and Commissioning Manual Subject to change without notice Landis Gyr 1 Lysander Drive Northfields Industrial Estate Market Deeping Peterborough PE68FB www Landisgyr com Tel 44 1778 349700 Fax 44 1778 349701 ...

Page 3: ..._________________________5 3 Installation Procedure ___________________________________________________ 6 4 The Service Menu_______________________________________________________ 8 4 1 The Service Menu sequence _________________________________________________8 4 2 Accessing the Service Menu _________________________________________________8 5 Installation_______________________________________ E...

Page 4: ...e applies to the G130 Smart Ready Gas meter E6 residential gas meter 1 2 Purpose This manual contains information required to install and commission the G130 Smart meter 1 3 Target Group The contents of this user manual are intended for technically qualified personnel of energy supply companies responsible for system planning installation and commissioning operation maintenance decommissioning and...

Page 5: ...is user manual are sufficiently qualified strictly observe the safety regulations and the operating information in the individual chapters In particular the owner of the meter bears responsibility for the training of personnel 2 3 Safety Regulations The following safety regulations must be observed at all times This equipment does not contain an Emergency Control Valve Means for shutting off the s...

Page 6: ...r requires no maintenance by the end user The external surfaces may be cleaned if required using a damp or anti static cloth 3 2 The safe removal of the existing meter 1 Isolate the gas supply via the Emergency control valve or other locally defined methodology 2 Record any necessary details such as outgoing meter serial number and the outgoing meter volume index 3 Store outgoing meter for return ...

Page 7: ...uld be followed G130 Valve Status displays 3 5 Display cycle The full display cycle is shown in the diagram below Press A or B to wake the display The index display is then shown Pressing button A will then show the valve status display Another press of button A or a timeout will return to the default display Holding button A whilst in the default display will enter the Rolling Register display se...

Page 8: ...characters are entered pressing button A until the desired character is shown in that position Pressing button B will move to the next character on the right It is possible to roll around back to the beginning if necessary to correct errors Holding button B for more than 3 seconds causes the meter to check the PIN code against the entered one If the PIN code is correct access to the menus is grant...

Page 9: ...Issue 1 9 10 G130 Installation and Commissioning July 2012 ver 01 2012 Landis Gyr Ltd 5 Rolling Register Displays The G130 has a single rolling register which displays the module firmware version ...

Page 10: ...ible to initiate a valve open process as follows Press button B Release button B Confirm Appliances are off by pressing button A Hold button A until display changes to next Release button A Wait for valve to open 30 seconds Default display Valve Open If the High Flow Open Interlock option is active and causes the valve to reclose then the Press B for Gas display will become available again Repeat ...

Reviews: