34/38
Released
Information Functions
© Gyr (Pty) Ltd
Cashpower Gemini PLC
– User Guide
11.15 Meter (Changeable) Option Register 0 (Register 035)
The meter displays the functions personalised at the time of manufacture. These functions can be
subsequently changed via a voucher:
Meter (Changeable) Option Register 0
Display
Function
(bracketed values apply for bit set to
1
)
1
XXX XXXX
Not used
X
1
XX XXXX
Not used
XX
1
X XXXX
Tamper detect sensing switch (enabled)
XXX
1
XXXX
Don‟t tamper (do tamper) on significant reverse energy
XXXX
1
XXX
(Disconnect) load switch on power fail
XXXX X
1
XX
Amps (Watts) power limit display
XXXX XX
1
X
Automatic (non-automatic) load switch closing after power limit trip
XXXX XXX
1
Display credit register or (display total register) on meter as default
display
11.16 Meter (Display) State Register 0 (Register 037)
The meter displays various states that are determined each time the meter starts up or that occur
during normal operation. They are not stored in EEPROM:
Meter (Display) State Register 0
Display
Function
1
XXX XXXX
Meter out of (in) creep lock
X
1
XX XXXX
Not used
XX
1
X XXXX
Not used
XXX
1
XXXX
Tamper detect sensing switch state (open)
XXXX
1
XXX
No EEPROM (EEPROM) error detected
XXXX X
1
XX
Not used
XXXX XX
1
X
50 (60) Hz mains frequency detected
XXXX XXX
1
Not used
11.17 Software Version Number (Register 048)
The meter displays the software version number masked into the microprocessor.
11.18 Power-Fail Counter (Register 050)
The meter displays the number of power failures that have occurred. This register is cleared with the
entry of a
tamper
reset voucher
– 7.5.1.4.
11.19 Last (STS only) Voucher ID in Time Format (Register 053)
The meter displays the time of issue of the last CTN entered.
11.20 Last (STS only) Voucher ID in Date Format (Register 054)
The meter displays the date of issue of the last CTN entered.
11.21 Last Voucher Entered (Register 055)
For STS meters, the voucher identifier is displayed (0
– 16777215) i.e. number of minutes elapsed
since 01:01:1993.
For CTS meters it is a sequence number.