13.29 Total Units Counter
– 0.001kWh Resolution (Register 061)
The meter displays the value of the total units register with a resolution of 0.001kWh. The most
significant digit of the display (if in use) will be “pushed” off the display in this mode.
13.30 Current Credit Register
– 0.000001kWh Resolution (Register 062)
The meter displays the value of the current credit register with a resolution of 0.000001kWh. The
most significant digits of the display (if in use) will be “pushed” off the display in this mode. This is a
very high resolution display that allows one to view both the incrementing of the credit register by the
DAE at 15-second intervals as well as it decrementing due to the energy consumed by any connected
load.
13.31 DAE Accumulated Credit Register
– 0.000001kWh Resolution
(Register 063)
The meter displays the value of the total credit entered into the meter via the DAE method with a
resolution of 0.000001kWh. The most significant digits of the display (if in use) will be “pushed” off the
display in this mode. This is a very high resolution display that allows one to view the incrementing of
the credit register by the DAE at 15-second intervals.
13.32 DAE 15-Second Portion Register
– 0.000001kWh Resolution
(Register 064)
The meter displays the energy value that gets added to the current credit register every 15 seconds
with a resolution of 0.000001kWh. The most significant digi
ts of the display (if in use) will be “pushed”
off the display in this mode.
13.33 Low Credit Level
– 0.000001kWh Resolution (Register 065)
The meter displays the level at which the lower two credit wedges on the LCD come into operation
with a resolution of 0.000001kWh. Note that this function is handled differently when the meter is
operating in Energy Limiting Mode
– refer to section 11.
13.34 Latch Inhibit Timer
– 1-Minute Resolution (Register 066)
When the load switch has opened due to either a power limiting event or expiry of DAE and is in a 30-
minute lockout state, the register displays the time remaining before the load switch will close again.