Carburation learning procedure 

LANDI RENZO S.p.A.

Installation and adjustament manual Lambda Control System/2

19/38

outlet located on the LCS/2 Computer wiring,

4) Use the Programming Tester V05 (or the per-

sonal computer) to adequate option per option
the parameters of LCS/2 Computer to the speci-
fication of the vehicles (see par. 7.2).

5) Check that the set values on LCS/2 Computer

are exactly correspondent to the characteris-
tics of the vehicles. If not, reset the memory of
LCS/2 and check that it memorise the stan-
dard values pointed out in bold type on the para-
graph 7.2; after, set another time the param-
eters of LCS/2 Computer and repeat the verify.

6) Start the car with the Switch / Gauge LCS/2 in

petrol position and wait a few minutes for the
lambda sensor to heat up.

7) Enter in the ‘DISPLAY’ page of the Program-

ming Tester V05 (or personal computer).

8) With the car stopped, switch to gas and per-

form a series of gradual accelerations and
decelerations at intervals of a few seconds; this
way, the LCS/2 computer will learn TPS mini-
mum position.

9) At this point the flow of gas at medium and

high speed must be regulated: bring the en-
gine to approx. 3,500 rpm (

][]], ]][]

) until

the default value has been learnt (the 

DEF

 value

on the Programmer Tester display will change).
The lambda probe learning range indicator, on
the data display page, will begin to swing indi-
cating correct operation of the system at full
speed.

10) Gradually drop the engine speed to minimum.

By displaying the page relating to the low-speed
actuator, make sure the engine is running at
slow speed (

m [] M

) and leave in this condi-

tion for 2 min. After 2 min, the lambda probe
learning range indicator will start to swing (the

DEF

 value on the Programmer Tester display

will change), thus indicating that optimum car-
buration at slow speed has been achieved. The
slow speed default is automatically changed
by the LCS/2 computer after one minute’s op-
eration at slow speed.

11) Make sure all the speeds correctly oscillate the

LEDs of the lambda scale indicating carbura-
tion.

12) After a few seconds, the lambda signal will be-

gin shifting, indicating that the carburation has
been learned.

13) Using the exhaust analyser, make sure the

lambda value is around 1,000 and that the CO,
HC and CO

2

 values are those shown in the in-

structions of the 

LANDI RENZO reducer instal-

lation and adjustment tables.

14) After acquiring default of the slow-speed ac-

tuator (att-min) and of the medium and high-
speed actuator (att-Max), perform a road test.

The data, descriptions and illustrations are merely
approximate and LANDI RENZO S.p.A. reserves
the right to make improvements or changes at its
own discretion and without prior notice.

The reducer shown in the cover picture is supplied
separately from the LCS/2.

Summary of Contents for LAMBDA CONTROL SYSTEM/2

Page 1: ...678 Fax 39 0 522 382 906 E mail info landi it Internet Site http www landi it GB MANUALE INSTALLAZIONE E REGOLAZIONE pag 6 MANUEL AND ADJUSTMENT MANUAL page 20 INSTALLATION AND ADJUSTMENT MANUAL page...

Page 2: ...Technical Drawings SchemiTecnici Sch masTechniques EsquemaT cnicos LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 2 38 Fig 1...

Page 3: ...Technical Drawings SchemiTecnici EsquemaT cnicos Sch masTechniques LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 3 38 Fig 2...

Page 4: ...Technical Drawings SchemiTecnici Sch masTechniques EsquemaT cnicos LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 4 38 Fig 4 Fig 3 Fig 5 Fig 6 Fig 7...

Page 5: ...Technical Drawings SchemiTecnici EsquemaT cnicos Sch masTechniques LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 5 38 Fig 8 Fig 9 Fig 10...

Page 6: ...apertura farfalla in fase di accelerazione Minima massima apertura attuatore Opzione cut off Opzione default fisso Reset memoria 1 2 ATTUATORE ELETTROMECCANICO LINEARE Caratteristiche elettriche Tensi...

Page 7: ...ll interno del compu ter 4 INSTALLAZIONE ATTUATORE ELETTROMECCANICO LINEARE Fig 4 4 1 ATTUATORE MINIMO REGIME ATT MIN Il riduttore con attuatore elettromeccanico lineare deve essere posizionato parall...

Page 8: ...ONDA LAMBDA Il collegamento della sonda lambda al cablaggio LCS 2 Fig 6 viene generalmente effettuato tra mite l interruzione del filo del segnale lambda ed il collegamento dei due capi ottenuti ai ri...

Page 9: ...iniettori benzina di funzionare mentre quando il motore alimen tato a benzina i contatti restano chiusi Impostare il computer LCS 2 alla voce TEMPO DI SOVRAPPOSIZIONE il tempo desiderato in secon di...

Page 10: ...cca Nella seconda pagina att indica in numero di passi la posizione in tempo reale dell attuatore elettromeccanico linea re per il minimo def indica in numero di passi la posizione di default acquisit...

Page 11: ...o viene visualizzato se il tempo di sonda sconnessa maggiore di 0 5 Il parametro viene visualizzato se l opzione di affondata abilitata 6 Il parametro viene visualizzato se l opzione cut off abilitata...

Page 12: ...pecifiche del veicolo e ripetere la verifica 6 Avviare il motore con il commutatore indicato re LCS 2 in posizione benzina ed attendere qualche minuto per permettere alla sonda lambda di scaldarsi 7 E...

Page 13: ...ion Fixed default option Memory resetting 1 2 LINEAR ELECTROMECHANICAL ACTUATOR Electrical specifications Power supply 12V Power absorption 150mA Nominal power 2W Operating temperature 20 C 120 C Wate...

Page 14: ...rked by the RED terminal from computer LCS 2 in the connector on the actuator For more details refer to the STEP MOTOR re ducer installation instructions inside the reducer pack 4 2 MEDIUM HIGH SPEED...

Page 15: ...t of the most common types of lambda probes Single wire lambda probe determine the wire linking the lambda probe and the petrol computer Fig 6A two wire lambda probe determine the lambda signal wire u...

Page 16: ...ICAL ACTUATOR CONNECTION The connector with the RED sheath on the end must be connected to the linear electromechani cal slow speed actuator att min located on the reducer SE81 STEP MOTOR part O Fig 1...

Page 17: ...g position NOTE the electromechanical linear actuator of the medium and peak speeds is indicated on the dis play of the Programmer Tester V05 by the mes sage att Max the electromechanical linear slow...

Page 18: ...RENZO MT012 The lambda sensor emulation of vehicles with Monoinjector Bosch for which the parameter TYPE OF TPS MONO BOSCH is made programming the parameter TYPE OF EMULATION GROUND On this vehicles t...

Page 19: ...a probe learning range indicator on the data display page will begin to swing indi cating correct operation of the system at full speed 10 Gradually drop the engine speed to minimum By displaying the...

Page 20: ...PS senseur position papillon Type senseur indicateur niveau gaz Type sonde lambda Retard lecture sonde lambda Type mulation sonde lambda Option maximum ouverture papillon en Acc l ration Minimum maxim...

Page 21: ...TEUR ELECTRO MECANIQUE LINEAIRE Fig 4 4 1 ACTIONNEUR DE RALENTI ATT MIN Le d tendeur avec actionneur lectrom canique lin aire doit tre positionn parall lement au sens de marche du v hicule Introduire...

Page 22: ...circuit de c blage du LCS 2 Fig 6 s effectue g n ralement en sectionnant le fil du signal lambda et en raccor dant les deux fils ainsi obtenus aux fils gris et vio let de l ordinateur LCS 2 Sur certai...

Page 23: ...nd le moteur est aliment l essence les contacts restent fer mes Entrer l Ordinateur LCS 2 au param tre TEMPS DE SUPERPOSITION le temps n cessaire en se conds de retard de l ouverture de les contacts e...

Page 24: ...en nombre de pas la position par d faut valeur standard de l actionneur lectrom canique lin aire de ralenti TOURS indique in t min le r gime moteur en temps r el TPS indique en volt la position du cap...

Page 25: ...programm sur ONDE CARREE 4 Le param tre s affiche si le temps de sonde d connect e est sup rieur 0 5 Le param tre s affiche si l option acc l rateur fond est ABILITE 6 Le param tre s affiche si l opti...

Page 26: ...teur LCS 2 en position essence et attendez quelque minute pour permettre a la sonde lambda de se chauffer 7 Entrer dans la page VISUALISATION duTesteur Programmateur ou du personal computer 8 Avec le...

Page 27: ...ectura sonda lambda Tipo emulaci n sonda lambda Opci n m xima abertura mariposa en fase de aceleraci n M nima m xima abertura actuador Opci n cut off Opci n default fijo Reset memoria 1 2 ACTUADORE EL...

Page 28: ...er dirigido hacia abajo para evitar que eventua les gotas de agua penetre dentro del Computer 4 INSTALACION ACTUADOR ELECTRO MECANICO LINEAR Fig 4 4 1 ACTUADOR R GIMEN RALENT ATT MIN El reductor con a...

Page 29: ...riginal del im planto el ctrico del veh culo ex masa del computer gasolina o masa de otros dispositivos como ABS etc 6 2 HILOS GRIS Y VIOLETA DE CONEXI N SONDA LAMBDA La conexi n de la sonda lambda al...

Page 30: ...r nivel gas 6 7 HILOS AMARILLOS EXCLUSION INYECTORES Los hilos amarillos del cableado LCS 2 son co nectados a los contactos de un rel normalmente cerrado Durante el funcionamiento a gas Fig 9A los con...

Page 31: ...el TPS est en fase dei m nimo de velocidad de crucero o de m xima abertura de la mariposa de aceleraci n R M indican si la sonda es en fase de mezcla pobre o rica att indica en n mero de pasos la pos...

Page 32: ...Actuador Max default fijo Deshabilitada habilitada Valor fijo default actuador Max 8 20 240 pasos Actuador min default fijo Deshabilitada habilitada Valor fijo default actuador min 9 20 160 pasos 1 E...

Page 33: ...el veh culo ver par 7 2 5 Verificar de haber memorizado en el Computer LCS 2 las opciones exactamente correspon diente a las caracter sticas del veh culo En caso contrario hacer un reset de la memoria...

Page 34: ...res por defecto del actuador del ralent att min y del actuador de los reg menes medios y altos att Max efec tuar un ensayo en carretera Datos descripciones e ilustraciones tienen un va lor meramente i...

Page 35: ...A CONTROLLO ELETTRONICO SENZA LIMITAZIONI DI CILINDRATA PUO ESSERE MONTATO SUI VEICOLI RISPONDENTI ALLE DIRETTIVE 88 76 CEE 89 458 CEE SE CATALIZZATI 91 441 CEE 93 59 CEE SISTEMA DI ALIMENTAZIONE A G...

Page 36: ...tico sia per il complesso di trasformazione a metano che a GPL CENTRALINA COMPUTERIZZATA DI CONTROLLO LANDI RENZO S p A LCS A G DGM 48522 GPL DEL 24 1 94 LCS A M DGM 48523 GM DEL 24 1 94 PUNZONATURA D...

Page 37: ...A CONTROLLO ELETTRONICO SENZA LIMITAZIONI DI CILINDRATA PUO ESSERE MONTATO SUI VEICOLI RISPONDENTI ALLE DIRETTIVE 88 76 CEE 89 458 CEE SE CATALIZZATI 91 441 CEE 93 59 CEE SISTEMA DI ALIMENTAZIONE A M...

Page 38: ...itivo attuatore di flusso e identico sia per il complesso di trasformazione a metano che a GPL LANDI RENZO S p A LCS A G DGM 48522 GPL DEL 24 1 94 LCS A M DGM 48523 GM DEL 24 1 94 PUNZONATURA DGM 5666...

Reviews: