Maintenance

It is advisable, periodically, to visually inspect the 
burner. Check air inlet to make sure it is not clogged or 
blocked. Wipe off any oil spills and keep this equipment 
clean and dry.

The flow of combustion and ventilating air to the burner 
must not be blocked or obstructed in any manner.

The area around the Landa washer should be kept 
clean and free of combustible materials, gasoline and 
other flammable vapors and liquids.

Unloader Valves

WARNING: The unloader valve on this pressure 
washer has been factory set and sealed and is a 
field nonadjustable part. Tampering with the 
factory setting may cause personal injury and/or 
property damage, and will void the manufacturer 
warranty.

AVERTISSEMENT: La soupape de décompression 
sur cette laveuse à pression a été réglée en usine, 
puis scellée, et est une pièce non réglable. L'altéra-
tion du paramètre de l'usine pourrait causer des 
lésions corporelles et/ou des dommages à la 
propriété, et annulera la garantie du fabricant.

Winterizing Procedure

Damage due to freezing is not covered by warranty. 
Adhere to the following cold weather procedures 
whenever the washer must be stored or operated 
outdoors under freezing conditions.

During winter months, when temperatures drop below 
32°F, protecting your machine against freezing is 
necessary. Store the machine in a heated room. If this 
is not possible then mix a 50/50 solution of antifreeze 
and water in the float tank. Turn the engine on to siphon 
the antifreeze mixture through the machine. If 
compressed air is available, an air fitting can be 
screwed into the float tank by removing the float tank 
strainer and fitting. Inject the compressed air. Water will 
be blown out of the machine when the trigger on the 
spray gun is opened.

High Limit Hot Water Thermostat

For safety, each machine is equipped with a tempera-
ture sensitive high limit control switch. In the event that 
the water should exceed its operating temperature, the 
high limit control will turn the burner off until the water 
cools then automatically reset itself. The thermostat 
sensor is located on the discharge side of the heating 
coil. The thermostat control dial is located on the 
control panel.

Pumps

Use only SAE 10W-40 weight non-foaming oil. Change 
oil after first 50 hours of use. Thereafter, change oil 
every year or at 500 hour intervals. Oil level should be 
checked through use of dipstick found on top of pump, 
or the red dot visible through the oil gauge window. Oil 
should be maintained at that level.

Cleaning of Coils

In alkaline water areas, lime deposits can accumulate 
rapidly inside the heating coil. This growth is increased 
by the extreme heat build up in the coil. The best 
prevention for liming conditions is to use high quality 
cleaning chemicals. In areas where alkaline water is an 
extreme problem, periodic use of Landa Coil Descaler 
(part #8.914-296.0) will remove lime and other deposits 
before coil becomes plugged. 

Periodic descaling of the heating coil is recommended 
so please consult your local Landa Dealer for instruc-
tions.

Removal of Soot and Heating Coil

In the heating process, fuel residue in the form of soot 
deposits may develop on the heating coil pipe and 
block air flow which will affect burner combustion. 
When soot has been detected on visual observation, 
the soot on the coil must be washed off after following 
the coil removal steps (See Coil Removal).

Pressure Relief Valve

Each machine is equipped with a relief valve to relieve 
pressure in the system when higher than normal 
operating pressures are encountered or if the unloader 
valve should fail. Unusually high pressures come from 
an object plugging the spray nozzle. If operating 
pressure is found to be normal and the relief valve 
continues to leak, repair or replace valve. 

CAUTION: This valve must be opened each year to 
check operation.

ATTTENTION: Cette soupape doit être ouverte 
chaque année pour vérifier le fonctionnement.

Rupture Disk

If pressure from pump or thermal expansion should 
exceed safe limits, the rupture disk will burst allowing 
high pressure to be discharged through hose to ground. 
When disk ruptures it will need to be replaced.he 
Rupture Disk should be replaced every two years.

Landa SLT/SLX Gas Operator’s Manual  8.914-002.0 - AR

Summary of Contents for SLT6-32324E 1.110-520.0

Page 1: ...ts i e pain t thin ner gas olin e oil Tri s odiu m pho sph ate prod ucts Amm onia prod ucts Acid bas ed prod ucts The se che mic als will harm the unit and will dam age the surf ace bein g clea ned Us...

Page 2: ...2 Landa SLT SLX Gas Operator s Manual 8 914 002 0 AR Machine Data Label...

Page 3: ...nloader Valves 15 Winterizing Procedure 15 High Limit Hot Water Thermostat 15 Pumps 15 Cleaning of Coils 15 Removal of Soot and Heating Coil 15 Pressure Relief Valve 15 Rupture Disk 15 Fuel 16 Burner...

Page 4: ...good working condition They are listed in this general order Storage Engine Maintenance Unloader Valves Winterizing Procedure High Limit Hot Water Thermostat Pump Cleaning of Coils De liming Coils Rem...

Page 5: ...e used only by trained opera tors Important Safety Information WARNING To reduce the risk of injury read operating instructions carefully before using AVERTISSEMENT Pour r duire le risque de blessures...

Page 6: ...ray flammable liquids AVERTISSEMENT Risque d incendie Ne pas pulv riser de liquides inflammables 7 Allow engine to cool for 1 2 minutes before refueling If any fuel is spilled make sure the area is dr...

Page 7: ...mage Keep clear of nozzle Use caution when oper ating Do not direct discharge stream at people or animals or severe injury or death will result AVERTISSEMENT La haute pression g n r e par ces machines...

Page 8: ...eam explosion 26 Do not overreach or stand on unstable support Keep good footing and balance at all times 27 Do not operate this machine when fatigued or under the influence of alcohol prescription me...

Page 9: ...ump damage Landa SLT SLX Gas Operator s Manual 8 914 002 0 AR Nev er Use Ble ach chlo rine pro duc ts and oth er cor ros i v e che mic als Liqu ids con tain ing solv ent s i e pain t thin ner gas olin...

Page 10: ...ty latch on the spray gun trigger STEP 8 Fill gasoline tank and check engine oil level Fill fuel oil tank Do not confuse gasoline and fuel oil tanks Keep proper fuel in proper tank Read engine manual...

Page 11: ...1 pour pr venir les dommages la surface et l injection et les blessures STEP 2 Read engine manual provided and pull choke Pull spray gun trigger to relieve pressure Then turn the engine switch to the...

Page 12: ...pray at a slight angle Recommendations Before cleaning any surface an inconspicuous area should be cleaned to test spray pattern and distance for maximum cleaning results If painted surfaces are peeli...

Page 13: ...f and continue spraying allowing the water to cool to below 100 STEP 4 Squeeze trigger on spray gun to relieve remaining pressure STEP 2 Turn engine key switch off STEP 3 Turn off water supply Landa S...

Page 14: ...TE The use of a fuel additive such as STA BIL or an equivalent will minimize the formulation of fuel deposits during storage Such additives may be added to the gasoline in the fuel tank of the engine...

Page 15: ...omatically reset itself The thermostat sensor is located on the discharge side of the heating coil The thermostat control dial is located on the control panel Pumps Use only SAE 10W 40 weight non foam...

Page 16: ...t Turn the adjusting screw located at the regulator port clockwise to increase and counterclockwise to decrease Do not exceed 200 psi or lower the pressure below 130 PSI when checked at the post pump...

Page 17: ...ditional burner component information see Burner Assembly page It is recommended that the oil burner be serviced yearly or as needed Contact your local service center Burner Air Adjustment To adjust s...

Page 18: ...high altitude main jet in the carburetor Contact your local authorized engine sales and service center for details Valves sticking Check and clean or replace if necessary Unloader valve seat faulty Ch...

Page 19: ...COLD START ONLY WHEN BURNER IS OFF Fuel is improper or water is in fuel Drain tank and replace contaminated fuel Air adjustment is improper Readjust air bands on burner assembly Fuel pressure is low...

Page 20: ...ecessary EXCESSIVE VIBRATION IN DELIVERY LINE Irregular functioning of the valves Check and replace if necessary DETERGENT NOT DRAWING Air leak Tighten all clamps Check detergent lines for holes Restr...

Page 21: ...e of your pressure washer Perform maintenance more often under severe conditions Landa SLT SLX Gas Operator s Manual 8 914 002 0 AG Maintenance Schedule Pump Oil Non foaming SAE 10W 40 Inspect Oil lev...

Page 22: ...8 914 002 0 Printed in U S A...

Reviews: