STEP 1:
Attach a 5/8" water supply
hose to inlet connector. Minimum
flow should be 10 GPM depending
on model of machine.
STEP 4:
Attach the high pressure
hose to the spray gun using teflon
tape on hose threads.
STEP 7:
Check oil level by using
supplied dip-stick. Use SAE 10W-
40 non-foaming only.
STEP 2:
Attach high pressure hose
to discharge nipple using quick
coupler. Lock coupler securely by
pulling back coupler collar,
inserting onto discharge nipple and
pushing collar forward until secure.
STEP 5:
Before installing nozzle,
turn on water supply and run
machine allowing water to flush
through the system until clear. Pull
the spring-loaded collar of the wand
coupler collar back to insert your
choice of pressure nozzle.
CAUTION: Never replace nozzles
without engaging the safety latch
on the spray gun trigger.
STEP 8:
Fill gasoline tank and
check engine oil level. Fill fuel oil
tank. Do not confuse gasoline and
fuel oil tanks. Keep proper fuel in
proper tank. Read engine manual
provided.
STEP 3:
Attach variable pressure
control wand to spray gun using
teflon tape on threads to prevent
leakage.
STEP 6:
Release the coupler collar
and push the nozzle until the collar
clicks. Pull the nozzle to make sure
it is seated properly.
ATTENTION: Ne jamais
remplacer les buses sans
d'abord mettre le dispositif de
sécurité sur la détente du
pistolet pulvérisateur.
STEP 9:
Install proper battery
making sure that the red cable is
attached to the positive terminal.
Use a 12V group 24 style battery.
Landa SLT/SLX Gas Operator’s Manual 8.914-002.0 - AR
Garden
Hose
Water
Inlet
High
Pressure
Nozzle
High
Pressure
Hose
Discharge
Nipple
Collar
High Pressure
Hose
Spray
Gun
Safety
Latch
Trigger
Wand
Wand
Collar
High
Pressure
Nozzle
High
Pressure
Hose
Spray Gun
Fuel
Oil
Tank
Gasoline
Tank
Red
Cable
Dipstick