background image

6

Safety

Important Safety Information

WARNING: To reduce the risk of 
injury, read operating instructions 
carefully before using.

AVERTISSEMENT: Pour réduire le 
risque de blessures, lire attentive-
ment les instructions de 
fonctionnement avant l'utilisation

1. Read the owner's manual thor-

oughly. Failure to follow instruc-

tions could cause malfunction of the machine and 
result in death, serious bodily injury and/or property 
damage.

2. Know how to stop the machine and bleed pressure 

quickly. Be thoroughly familiar with the controls.

3. Stay alert — watch what you are doing.

4. All installations must comply with local codes. 

Contact your electrician, plumber, utility company 
or the selling dealer for specific details. If your 
machine is rated 250 volts or less, single phase a 
ground fault circuit interrupter (GFCI) will be 
provided. If rated more than 250 volts, or more 
than single phase this product should only be 
connected to a power supply protected by a GFCI.

DANGER: Improper connection of the equipment-
grounding conductor can result in a risk of electro-
cution. Check with a qualified electrician or service 
personnel if you are in doubt as to whether the 
outlet is properly grounded. Do not modify the plug 
provided with the product - if it will not fit the outlet, 
have a proper outlet installed by a qualified electri-
cian. Do not use any type of adaptor with this 
product

DANGER: Une mauvaise connexion du conducteur 
de terre de l'équipement peut entraîner un risque 
d'électrocution. Vérifier auprès d'un électricien 
qualifié ou du personnel d'entretien si vous avez 
des doutes quant à savoir si lasortie est 
correctement mise à la masse. NE PAS modifier la 
fiche fournie avec le produit - si elle n'entre pas 
dans la sortie, faire installer une sortie appropriée 
par un électricien qualifié. NE JAMAIS utiliser un 
adaptateur avec ce produit.

WARNING: Keep wand, hose, and 
water spray away from electric 
wiring or fatal electric shock may 
result.

AVERTISSEMENT: Garder la 
lance, le boyau et le jet d'eau à 
l'écart de tout câblage électrique 
ou des chocs électriques mortels 
pourraient survenir

5. To protect the operator from electrical shock, the 

machine must be electrically grounded. It is the 
responsibility of the owner to connect this machine 
to a UL grounded receptacle of proper voltage and 
amperage ratings. Do not spray water on or near 
electrical components. Do not touch machine with 
wet hands or while standing in water. Always 
disconnect power before servicing.

WARNING: Flammable liquids can create fumes 
which can ignite, causing property damage or 
severe injury.

AVERTISSEMENT: Des liquides inflammables 
peuvent produire des vapeurs qui peuvent 
s'enflammer, causant ainsi des dommages à la 
propriété ou des blessures graves.

WARNING: Risk of explosion — 
Operate only where open flame or 
torch is permitted.

AVERTISSEMENT: Risque d'explo-
sion- Utiliser uniquement dans des 
endroits où l'utilisation d'une 
flamme nue ou d'une torche est 
permise.

6. In oil burning models, use only 

kerosene, No. 1 home heating fuel, or diesel. If 
diesel is used, add a soot remover to every tankful.

WARNING: Risk of fire — Do not 
add fuel when the product is 
operating or still hot. 

AVERTISSEMENT: Risque 
d'incendie -Ne pas ajouter de 
carburant pendant que la machine 
fonctionner ou est encore chaude.

WARNING: Do not use gasoline 
crankcase draining or oil 

containing gasoline, solvents or alcohol. Doing so 
will result in fire and/or explosion.

AVERTISSEMENT: Ne pas utiliser d'essence, de 

Landa PHW Operator’s Manual   8.917-417.0 - D

WARNING

    READ OPERATOR’S 

 MANUAL THOROUGHLY 

           PRIOR TO USE.

OPERATIONS

SAFET

Y

MAINTENANCE

       

KEEP WATER 

 SPRAY AWAY FROM 

ELECTRICAL WIRING.

WARNING

WARNING

RISK OF EXPLOSION: 

OPERATE ONLY WHERE 

OPEN FLAME OR TORCH 

IS PERMITTED

WARNING

RISK OF FIRE. 

DO NOT ADD FUEL 

WHEN OPERATING

MACHINE.

Summary of Contents for PHW3-11024

Page 1: ...a y gun and wand SUP ERF ICIE S CAL IENT ES Use solam ente las rea s aisla das del gatill o y la lanza SUR FAC ES CHA UDE S Touc her seule men t les parti es isol es des poig n e pisto lets et lance s...

Page 2: ...2 Landa PHW Operator s Manual 8 917 417 0 D Machine Data Label...

Page 3: ...nce 14 Maintenance And Service 14 Pump Lubrication 14 Fuel 14 Electrode Setting 14 Transformer Check 14 Fuel Control System 14 Fuel Pressure Adjustment 14 Wayne Oil Burner 15 Fuel Pressure Adjustment...

Page 4: ...preventive main tenance to keep the machine and its components in good working condition They are listed in this general order Preventative Maintenance Maintenance And Service Pump Lubrication Fuel B...

Page 5: ...he operator in the operator s native language by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufactu...

Page 6: ...fi NE JAMAIS utiliser un adaptateur avec ce produit WARNING Keep wand hose and water spray away from electric wiring or fatal electric shock may result AVERTISSEMENT Garder la lance le boyau et le jet...

Page 7: ...nes ou des animaux car cela risquerait de causer des blessures graves ou m me la mort WARNING This machine produces hot water and must have insulated components attached to protect the operator AVERTI...

Page 8: ...utiliser l int rieur m me si les fen tres et les portes sont ouvertes 17 Avoid installing machines in small areas or near exhaust fans Adequate oxygen is needed for combustion or dangerous carbon mono...

Page 9: ...art unit turn switc h on gr ip wan d se curel y and trigg er spra y gun 7 To hea t wate r turn burn er switc h on 8 To app ly dete rgen t see Ope rator s Man ual 9 To shut dow n mac hine turn burn er...

Page 10: ...must be used refrain from using 90 bends If the pipe can not go straight up then use only 45 bends and go to the next larger size pipe The overall pipe length must not exceed 6 feet in length Air adju...

Page 11: ...p en flam e ch is pe rm it t sp ray ids ARNING AV ER TISS EM EN T RIE SG O DE EX PL OS IO N Us e el pro du cto en re as do nd e el fue go llam a se an pe rm itid os No roc ie liqu i do s infl am ab le...

Page 12: ...ater Place detergent suction tube directly into cleaning solution and apply to surface at low pressure for best results limit your work area to sections approximately 6 feet square and always apply de...

Page 13: ...f frozen FREEZE DAMAGE IS NOT COVERED BY WARRANTY ATTENTION Toujours entreposer la laveuse pression dans un endroit o la temp rature ne sera pas inf rieure X C X F La pompe sur cette machine est susce...

Page 14: ...uel tank and replace fuel filter every 100 hours of opera tion Electrode Setting Ignition Circuit Periodically inspect wires spring contact and elec trodes for condition security and proper spacing Tr...

Page 15: ...et can impact fuel flow In more extreme tempera tures this local site adjustment may also require different fuel nozzles for fuel inlet temperatures that are at seasonal extremes higher or lower in lo...

Page 16: ...mage due to freezing is not covered by warranty Adhere to the following cold weather procedures whenever the washer must be stored or operated outdoors under freezing conditions During the winter mont...

Page 17: ...valve is installed next to the inlet side of the pump that will open in the event the water tempera ture exceeds 140 F Therefore while operating the machine do not leave the spray gun closed for an e...

Page 18: ...e more often under severe conditions Maintenance Schedule Replace Fuel Lines Annually Pump Oil 10W 40 Non Foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours o...

Page 19: ...Oil Change Record DateOilChanged Month Day Year Estimated Operating Hours Since Last Oil Change DateOilChanged Month Day Year Estimated Operating Hours Since Last Oil Change Landa PHW Operator s Manua...

Page 20: ...tage of building and compare with require ments Obtain a different power source Detergent metering valve left open sucking air or faulty metering valve Close and or replace metering valve BURNER WILL...

Page 21: ...tank and replace contaminated fuel Improper air adjustment Readjust air bands on burner assembly Low fuel pressure Adjust higher Air leaks in fuel lines Check fuel lines for leaks or air bubbles Tight...

Page 22: ...itch tripped Allow motor to cool switch will automatically reset Motor wet Allow to dry Short in electrical wiring Wire contacts should be clean and tight No breaks in wires Coil liming up causing exc...

Page 23: ...fective Replace valve Particle next to poppet Remove internal parts and clean BURNER STAYS ON WHEN SPRAY GUN IS IN OFF POSITION Fuel pump pressure too high Readjust fuel pressure Pressure switch defec...

Page 24: ...retainer worn Check and replace if necessary Cracked ceramics Check and replace if necessary OIL DRIPPING Oil seal worn Check and replace if necessary Cracked manifold Check and replace if necessary...

Page 25: ...ISCHARGE LINE DURING BYPASS MODE Pressure adjustment too tight Call your local dealer Restricted bypass line Bypass line should be 1 2 inside diameter I D 12 long and of low pressure flexible hose Flo...

Page 26: ...8 917 417 0 Printed in U S A...