background image

Maintenance

Please consult your local 

LANDA

 Dealer for the correct

procedures.

To Adjust:

 Start machine and turn burner ON. Loosen

two locking screws found in the air shutter openings

(refer to illustration) and close air shutter until black

smoke appears from burner exhaust vent. Note air

band position. Next, slowly open the air shutter until
white smoke just starts to appear. Turn air shutter

halfway back to the black smoke position previously

noted. Tighten locking screws.

If the desired position cannot be obtained using only

the air shutter, lock the air shutter in as close a position

as can be obtained, the
Adjust to your operating location's environment as-

needed  for best smoke  spot  and performance

compliant with local, state, and federal regulations.

CAUTION: If white smoke appears from burner

exhaust vent during start-up or operation, discontinue

use and readjust air bands.
ÚTTENTION: Si de la fumée blanche s'échappe de

l'évacuation du brûleur pendant le démarrage ou le

fonctionnement, cesser d'utiliser et réajuster les

bandes d'air.
PRECAUCIÓN: Si se presenta humo blanco del

escape del quemador durante el arranque u opera

-

cion, detenga la operacion y reajuste las bandas de

aire.

Initial Air Adjustments:

 Allow sufficient air to obtain a

clean burning flame by loosening the lock screws and

moving the air shutter and if necessary the bulk air

band.
Reduce the air supply until the flame tips appear

slightly smoky, then increase the air just enough to

cause the flame tips to appear absolutely clean.

Removal of Soot and Heating Coil

In the heating process, fuel residue in the form of soot

deposits may develop between the heating coil pipe

and block air flow which will affect burner combustion.

When soot has been detected on visual observation,

the soot on the coil must be washed off. Follow these

steps to remove the coil.
1. Disconnect hose from pump/unloader to inlet side

of the coil.

2. Disconnect electrical connection to the thermostat

or remove thermostat sensor.

3. Remove  all  the  fittings  from  inlet  and  discharge

side of coil.

4. Remove burner assembly from combustion

chamber.

5. Remove the 5/16” cap nuts from each side of coil

and coil cover assembly (these cap nuts are used

to fasten cover and coil to chassis).

6. Disconnect  1/2”  pipe  nipples  from  inlet  and

discharge side of coil.

7. Remove top coil wrap exposing insulation and coil

and fold back insulation.

8. Remove bolts that hold down coil to bottom wrap.
9. Remove coil.
10. Replace or repair any insulation found to be torn or

broken.

Coil Reinstallation

Reinstall  new  or  cleaned  coil  by  reversing  Steps  9

through 1 above. 

Cleaning of Coils

In alkaline water areas, lime deposits can accumulate

rapidly inside the coil pipes. This growth is increased by

the extreme heat build up in the coil. The best preventa

-

tive for liming conditions is to use high quality cleaning

detergents. In areas where alkaline water is an extreme

problem, periodic use of Landa Coil Descaler (Landa

Part #8.914-296.0) will remove lime and other deposits

before coil becomes plugged. 

Periodic descaling of the heating coil is recom

-

mended so please consult your local Landa Dealer

for instructions.

Landa 2HOT Series Operator’s Manual - 

9.808-353.0

 

- A

Air 

Band

Fuel 

Pump

Air Adjustment 

Screw

Air Shutter

Locking Screws

18

Summary of Contents for 2HOT Series

Page 1: ...Hot Water Electric Powered Diesel Oil Heated Operator s Manual Pressure Washer MODELS 2HOT 2 15024D 1 109 177 0 2HOT 4 20024A 1 109 178 0 2HOT 4 20024G 1 109 179 0 For the Landa Dealer nearest you con...

Page 2: ...2 Landa 2HOT Series Operator s Manual 9 808 353 0 A Machine Data Label...

Page 3: ...n 14 Cleaning Tips 14 Rinsing 14 Shutting Down Clean up 15 Storage 15 Maintenance Preventative Maintenance 16 Unloader Valves 16 Winterizing Procedure 16 High Limit Hot Water Thermostat 16 Pumps 16 Ru...

Page 4: ...When placing an order for parts the machine model and machine serial number are important Refer to the MACHINE DATA box which is filled out during the installation of your machine The MACHINE DATA bo...

Page 5: ...FCI will be provided If rated more than 250 volts or more than single phase this product should only be connected to a power supply protected by a GFCI DANGER Improper connection of the equipment grou...

Page 6: ...de incendio No agregue combus tible cuando el producto est en funcionamiento o a n est caliente WARNING Do not use gasoline crankcase drainings or oil containing gasoline solvents or alcohol Doing so...

Page 7: ...iento de la lavadora a presi n 12 To reduce the risk of injury close supervision is necessary when a machine is used near children Do not allow children to operate the pressure washer This machine mus...

Page 8: ...ave adequate slopes and drainage to reduce the possibility of a fall due to slippery surfaces AVERTISSEMENT Faire preuve d une extr me prudence au moment d utiliser une chelle des cha faudages ou tout...

Page 9: ...sure Hose Detergent Bucket not included Brass Soap Power Cord Fuel Tank Nozzle Variable Pressure Control Wand Burner Switch Thermostat Garden Hose Inlet Connector Strainer Water Supply Hose not includ...

Page 10: ...he machine WARNING Avoid small areas or areas near exhaust fans AVERTISSEMENT viter les petites superficies ou les surfaces proximit des ventilateurs ADVERTENCIA Evitar reas peque as o cercanas a vent...

Page 11: ...zzles without engaging the safety latch on the spray gun trigger ATTENTION Ne jamais remplacer les buses sans d abord mettre le dispositif de s curit sur la d tente du pistolet pulv risateur ADVERTENC...

Page 12: ...ckwise to raise the pressure For hot water washing turn the burner switch and thermostat ON The burner will light automatically STEP 7 Fill fuel tank with proper fuel Use home heating oil or diesel fu...

Page 13: ...plied using the high pressure nozzle STEP 3 With the motor running pull trigger to operate machine Liquid detergent is drawn into the machine and mixed with water Apply detergent to work area Do not a...

Page 14: ...Javel produits base de chlore et autres produits chimiques corrosifs Liquides contenant des solvants c d diluant peinture essence huiles etc Produits base de tripolyphosphate de sodium Ammoniac ou pro...

Page 15: ...se congela DA OS POR CONGELAMIENTO NO ESTAN CUBIERTOS POR GARANT A 1 Stop the pressure washer squeeze spray gun trigger to release pressure 2 Detach water supply hose and high pressure hose 3 Turn on...

Page 16: ...he burner must not be blocked or obstructed in any manner Unloader Valves Unloader valves trap pressure in the line when a spray gun is closed Unloader valves are preset and tested at the factory befo...

Page 17: ...ow Transformer Check Burner Nozzle Keep the tip free of surface deposits by wiping it with a clean solvent saturated cloth being careful not to plug or enlarge the nozzle For maximum efficiency replac...

Page 18: ...Heating Coil In the heating process fuel residue in the form of soot deposits may develop between the heating coil pipe and block air flow which will affect burner combustion When soot has been detect...

Page 19: ...foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean Burner Filter Monthly More often if fuel quality is poor Remove Burner Soot From Heating...

Page 20: ...n a different power source LOW WATER TEMPERATURE Improper fuel or water in fuel Drain fuel tank and replace with proper fuel Low fuel pressure Increase fuel pressure Weak fuel pump Check fuel pump pre...

Page 21: ...erial plate for proper size Worn piston packing Check and replace if necessary FLUCTUATING PRESSURE Valves worn Check and replace if necessary Blockage in valve Check and replace if necessary Pump suc...

Page 22: ...lipping on fuel pump shaft or burner motor shaft Replace if needed ON OFF Switch defective Check continuity through burner switch Heavy sooting on coil and burner can cause interruption of air flow an...

Page 23: ...lush lines and replace nozzle Wrong spray nozzle See serial plate for minimum nozzle size Automatic overload switch tripped Allow motor to cool then push Red reset button Motor wet Allow to dry Short...