Page 28
Check and set pressure monitor
Deadly risk!
Working on open, live equipment!
• Do not operate the equipment with damp hands!
• Caution: live components!
Setpoint value switching pressure
Compressor
On
= 3.0 bar
Off = 5.5 bar
Check switch values
• Switch on operating voltage.
• Close shut-off valve (
9
).
•
Open safety valve "high pressure" (
25
) and observe
manometer "high pressure" (
13
).
- with a pressure drop below
3.0 bar
the compressor must
start.
• Close safety valve "high pressure" (
25
) and observe
manometer "high pressure" (
13
).
- with a pressure increase to
5.5
bar and furthermore the
compressor must switch off.
To set the switch values note the following:
•
Only set pressure monitor (36) under pressure!
9
25
36
•
Rotating the hand valve (81) causes approx. 0.6 bar change of switching pressure.
•
First set the cut-out pressure and then the cut-in pressure, because changing the cut-out pressure
leads to a change in the cut-in pressure. This means the difference between cut-out and cut-in
pressure stays the same.
•
Once the hand valve has been pressed down (81) the cut-in pressure can be adjusted separately
and the difference between the cut-out and cut-in pressure changed.
Set the switch values
• Lift up the plastic cover of the pressure monitor after
unfastening the four screws.
• Unscrew the lock pin (
82
) of the hand valve (
81
).
Set the cut-out pressure:
Raise cut-out pressure
• Turn hand valve (
81
) clockwise (pr)
Lower cut-out pressure
• Turn hand valve (
81
) anti-clockwise (pressure -)
81
82
Set the cut-in pressure:
Raise cut-in pressure
• Press down hand valve (
81
) and then turn clockwise
(difference -)
Lower cut-in pressure
• Press down hand valve (
81
) and then turn anti-clockwise
(diff)
After setting
• Screw in lock pin (
82
) in one of the two retainers.
• Put on the cover of the pressure monitor again and tighten.
Summary of Contents for RTS 1000D
Page 43: ...Page 43 Compressor VD 7 2 RTS 1000D and VD 28 2 RTS 2600D B...
Page 45: ...Page 45 Compressor VD 50 4 RTS 5200D...
Page 57: ...Compressor VD 7 2 and VD 28 2 Page 57...
Page 59: ...Page 59 Compressor VD 50 4...
Page 61: ...Page 61 Pneumatics diagram RTS 1000D RTS 2600D and RTS 5200D no 073445 072...
Page 63: ...Page 63 Circuit and wiring diagram RTS 1000D RTS 2600D und RTS 5200D no 073659 000...
Page 65: ...Page 65 Circuit and wiring diagram RTS 1000D RTS 2600D und RTS 5200D no 073586 000...
Page 66: ...Page 66...
Page 67: ...Page 67...