INSTALLATION

Unpack the Dispenser

1.  Set shipping carton upright on the floor then cut package 

banding straps and remove.

2.  Open top of carton and remove interior packaging. 
3.  Before removing the unit from shipping base, carefully 

remove all cladding in the following order to avoid damage 

during unit transfer from shipping base to counter top:

Selecting/Preparing a Counter Location

Inspection of Drain Spider

4.  Lift carton up and off of the unit.
5.  Remove plywood shipping base from unit by moving unit so 

that one side is off the counter top or table allowing access 

to screws on the bottom of the plywood shipping base.

6.  Remove accessory kit/loose parts from ice compartment.

 

Remove the items listed below in the following order:
1.  Ice Chute Lever
2.  Splash Plate - 

(Disconnect Wires Before Removal)

3.  Outer Nozzle
4.  Merchandiser - 

(Unscrew Top Merchandiser Screws 

Before Removal)

5.  Drip Tray/Cup Rest
6.  Side Panels

NOTE

 

If unit is to be transported, it is advisable to leave the 

unit secured to the plywood shipping base.

 

NOTE

 

The drain spider is located to the right side near the 

front of the bin under the ice shroud. The coldplate has 

a cavity designed to hold the drain spider. During 

 

shipment, the drain spider may become dislodged from 

its original position. Prior to installing the unit, ensure 

the drain spider is in the correct position. This will 

 

prevent drain clog issues. Inspect the lower bin area 

 

and reach under the shroud to ensure the drain spider 

is secure in the coldplate cutout. If the spider is not in 

place, proceed with the following steps.

NOTE

7.  If leg kit has been provided, assemble legs by tilting unit.

 

Inspect unit for concealed damage. If evident, notify 

 

delivering carrier and file a claim against the same.

NOTE

1.  Remove agitator clip and pin from agitator bar. 
2.  Remove agitator bar from the hub.
3.  Remove ice shroud by lifting the side opposite the auger and 

rotating out from beneath the auger.

4.  Locate drain spider and reinstall in the coldplate cavity where 

drain line exits.

5.  Reinstall all components. Ensure agitator clip is locked.

1.  Select a level, well ventilated location that is in close       

proximity to a properly grounded electrical outlet, within five 

(5) feet (1.5 m) of a drain, a water supply that meets the 

requirements shown in the Specifications section found on 

page 3, away from direct sunlight or overhead lighting, and 

has sufficient clearance for air circulation. 

2.  Sufficient clearance must be provided (if an ice maker is 

not installed) to allow filling ice compartment from a five (5) 

gallon bucket (a minimum of 16 inches is recommended).

3.  Inspect the counter location where the unit is to be installed. 

Verify the selected counter is strong enough to safely sup-

port the weight of the dispenser, the ice, and the icemaker 

(if necessary) after counter cut out is made. The total weight 

(with icemaker) for this unit could exceed 800 pounds (383.6 

kg).

 

The dispenser should only be installed in a location 

where it can be overseen by trained personnel

NOTE

4.  Unit may be installed directly on countertop or on legs. If 

installed directly on the counter, unit must be sealed to the 

countertop with an FDA approved sealant. If an icemaker is 

to be mounted on top of dispenser, do not install dispenser 

on legs. 

5.  Select a location for the remote pump, syrup pumps, CO

2

 

tank, syrup containers, and water filter (recommended). 

6.  Using Counter Cutout Template provided, cut out required                                                                                      

opening for the water, syrup, and CO

2

 lines in the designated 

dispenser location.

 

The selected location should have sufficient clearance 

 

for the proximity sensor located in the front of the 

 

unit to be able to clearly identify any movement within 

 

its range. 

NOTE

1’  7”

6’  2”

1’  6”

10”

center line

 

Lancer does 

NOT

 recommend the use of shaved or

 

flake ice in the dispenser.

NOTE

Summary of Contents for TouchPoint

Page 1: ...s including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by...

Page 2: ...ter supply line must be at least a 3 8 inches 9 525 mm pipe with a minimum of 25 PSI 0 172 MPA line pressure but not exceeding a maximum of 50 PSI 0 345 MPA Water pressure exceeding 50 PSI 0 345 MPA m...

Page 3: ...r 2 Remove agitator bar from the hub 3 Remove ice shroud by lifting the side opposite the auger and rotating out from beneath the auger 4 Locate drain spider and reinstall in the coldplate cavity wher...

Page 4: ...y cord to a grounded electrical outlet of the proper voltage and amperage rating Installing an Icemaker if necessary When installing an icemaker on the dispenser use a bin thermostat to control the ic...

Page 5: ...Source D Line to Remote Pump 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection between the remote pump deck and car...

Page 6: ...achment nut ATTENTION A CO2 Regulator B 1 4 Nut Stem Seal C Line to CO2 Regulator Manifold D Oetiker Pliers A B C D A dedicated CO2 regulator is required to supply the CO2 inlet at the unit as well as...

Page 7: ...devices on the same outlet WARNING TouchPoint will begin booting up as soon as power is connected Boot up may take several minutes Cup selection carousel will appear when complete NOTE 7 Test the moto...

Page 8: ...n 4 Selecting the different tabs on the left side of the screen will reveal even more available brands Tap Back to return to Technicians Menu 5 Tap the desired syrup brand Selected brand will become d...

Page 9: ...syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives...

Page 10: ...plash Plate Assembly by lifting it up and out from the dispenser face Refer to the Automatic Agitation Warning on the first page of this manual NOTE It is recommended to perform this procedure monthly...

Page 11: ...syrup lines with BIB connectors into cleaning solution 8 Activate each valve for a minimum of sixty 60 seconds until lines are filled with cleaning solution then let stand for thirty 30 minutes 9 Flus...

Page 12: ...PLUMBING DIAGRAM ELECTRONICS DIAGRAM Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: