Siberian Elite Glycol Chiller 220V / 60Hz
www.lancerbeverage.com
Page 17 of 17
Hoshizaki Lancer reserve the right to change specifications without notice
Part No: 68000205
Images are for illustration purposes only as product may vary.
No 016
– 12 February 2016
13.
Manufacturer’s Checklist
Evacuate, charge with nitrogen and leak check all refrigeration components.
Liquid line and glycol solenoid installed in the correct flow direction.
TX valve refrigerant matches unit.
TX valve sensing bulb is secured tightly and in correct position, TX valve capillary not
rubbing on anything.
Air tape around TX bulb.
Turn on unit, check thermostat operates and solenoids energise.
Glycol probe in correct position and suction line probe checked for sensor tightness.
Confirm operation of glycol probe, check for temp change. As per SOP-PRD-094
Check pumps operate.
Check wiring to ensure no internal insulation is exposed.
All refrigeration tube work straight and not rubbing on other components.
Installation kit supplied.
Serial number plaque correctly positioned.
Tank area clean.
Supply manual.
All screws secure, ensure deck and lid are fully sealed.
Supply original checklist to unit, file copy.
Electrically Tested By: .......................................................................................
Inspection Number: ...........................................................................................
Checked by:.......................................................................................
Date: .... .....................................................
Work Order No: ................................................................................
Electrical
Continuity
Earth Continuity
Insulation
Affix label here