S8E V3 Hi-Carb Superchiller
230V / 50Hz
www.lancerbeverage.com
Page 6 of 27
Hoshizaki Lancer reserve the right to change specifications without notice.
Part No: 68000021
Images are for illustration purposes only as product may vary.
No 043-3 – 19 December 2019
2.5 Carbon Dioxide (CO2)
Warning
The Superchiller uses a CO
2
(Carbon Dioxide) supply. CO
2
is a heavier
than air, colourless, non-combustible gas with a faintly pungent odour.
Personnel exposed to high concentrations of CO
2
gas will experience
tremors, which are followed rapidly by loss of consciousness and
suffocation.
If a CO
2
gas leak is suspected, immediately ventilate the contaminated
area before attempting to repair the leak.
3. Installation
Warning
To avoid personal injury or damage, do not attempt to lift a Superchiller
without help.
Use of a mechanical lift is recommended.
(NOTE: Empty S8E Superchiller weight: 212kg)
3.1 Receiving
Each unit is completely tested under operating conditions and thoroughly inspected before
shipment. At time of shipment, the carrier accepts the unit and any claim for damage(s) must
be made with the carrier. Upon receiving units from the delivering carrier, carefully inspect
shipping crate for visible indication(s) of damage. If damage exists, have carrier note damage
on bill of landing and file a claim with the carrier.
3.2 Unpacking
Caution
The use of gloves is recommended to protect hands from potential injury
from sharp edges. The Superchiller must always be handled in a vertical
position.
Carefully unpack the Lancer S8E Superchiller from the shipping carton, remove the wooden
base.
If appropriate, assemble legs to unit by carefully tilting (tilt should not be more than 45°).
Inspect unit for concealed damage and if evident, notify delivering carrier and file a claim
against the carrier.
3.3 Selecting a Location
Warning
Superchillers are intended for indoor operation only; do not operate
outside unless suitably protected by a weatherproof enclosure.
This appliance is not suitable for installation in an area where a water jet
could be used.
Caution
The Superchiller is not suitable for use in subfreezing temperatures.
To prevent damage to the water supply line, turn off and drain unit when
air temperature is below zero.
•
The S8E Superchiller should be located in a well-ventilated, firm, level location close to
dispenser, water and electrical supplies, with easy access for servicing
•
Ensure sufficient clearance around Superchiller to allow good fresh air circulation through
the condenser – allow at least 200mm at rear and sides.
•
Installation should only be performed by a qualified and competent technician.
3.4 Mounting Superchiller
•
Install on a flat, level surface using adjustable legs or casters (Optional).
•
Fix to supporting structure using 4 x ¾” BSW bolts screwed into base supports.