7
Cleaning and Sanitizing Valves - Monthly
1. Disconnect product lines from pre-mix containers.
2. Remove product from tubing by purging with carbon dioxide.
3. Remove the valve head assembly by turning the connecting nut clockwise to loosen from mounting
sleeve.
4. Remove the plastic valve piston from the valve shank.
5. Using the cleaning solution and a clean cloth, clean the valve head assembly and valve piston and rinse
with warm, potable water.
6. Using the sanitizing solution and a clean cloth, sanitize the valve head assembly and valve piston and
set aside to air dry.
7. Using a clean cloth or small brush, clean and sanitize the inside of the valve shank and let air dry.
8. Reinstall compensator piston and valve head assembly to mounting sleeve and reconnect product lines
to pre-mix containers.
9.
Draw drinks to flush sanitizing solution left in valve. Taste the drink to verify that there is no off-taste. If
off-taste is found, flush product lines again.
Following sanitization, rinse with end-use product until there is no aftertaste. Do not use a fresh water
rinse. Residual sanitizing solution left in the system creates a health hazard.
!
CAUTION
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was purchased.
Comply with local regulations regarding disposal of the refrigerant and insulation.
Dispenser Disposal
F
A
B
C
D
E
A. Valve Head Assembly
B. Valve Piston
C. Valve Shank
D. Connecting Nut
E. Valve Body
F. Elbow