IMPORTANT SAFETY INSTRUCTIONS

READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT.

This manual contains important safety information and all applicable safety precautions must be observed. To reduce 

the risk of fire, damage to the equipment, or personal injury when using this unit all instuctions/warnings on the product 

being used must be followed:

 

Text following the Caution signal indicates a hazardous situation, which if not avoided, could result in death or serious 

injury. Be sure to read the Caution statements before proceeding with the installation.

CAUTION

 

Text following the Attention signal addresses a situation that if not followed could potentially damage the equipment. 

Be sure to read the Attention statements before proceeding

ATTENTION

 

Text following the Note signal provides you with information that may help you more effectively perform the 

 

installation procedures within this manual. Disregarding information will not cause damage or injury, however it may 

limit the performance of the dispenser. 

NOTE

•  This appliance 

should not be used by children or infirm persons without supervision. 

•  This appliance is not intended for use by persons (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have been given supervi-

sion or instruction concerning use of the appliance by a person responsible for their safety. 

•  This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been given 

supervision or instruction concerning use of the appliance in a safe way and understand the hazards 

involved.

•  Cleaning and user maintenance shall not be performed by children without supervision.
•  This unit is not a toy and children should be advised not to play with the appliance.
•  The min/max ambient operating temperature for the dispenser is 40°F to 105°F (4°C to 41°C). 
•  Do not operate unit below minimum ambient operation conditions. 
•  Should freezing occur, cease operation of the unit and contact authorized service technician.
•  The maximum tilt for safe operation is 5°. 
•  This appliance must be installed and serviced by a professional.

Intended Use

Summary of Contents for Pre-Mix Cooler

Page 1: ...ETTING STARTED Each unit is tested under operating conditions and is thoroughly inspected before shipment At the time of shipment the carrier accepts responsibility for the unit Upon receiving the uni...

Page 2: ...NOTE This appliance should not be used by children or infirm persons without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental c...

Page 3: ...5 inches 648 mm Depth 13 25 inches 336 5 mm Height 14 0 inches 356 mm FITTINGS Pre Mix Syrup Inlets 1 4 inch barb WEIGHT Shipping 40 lbs 18 14 kg Empty 35 lbs 15 88 kg With Ice 85 lbs 38 56 kg ICE Cap...

Page 4: ...gs 7 Clean and sanitize the ice bin See Cleaning and Sanitizing section on the next page for instructions 8 Fill the unit with ice then close the lid Inspect unit for concealed damage If evident notif...

Page 5: ...aches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives or solvents on the dispenser DO NOT use hot water above...

Page 6: ...Fill the unit with ice and close the lid Cleaning and Sanitizing Product Lines Monthly 1 Disconnect product lines from pre mix containers 2 Fill product lines with warm water to flush out any product...

Page 7: ...air dry 8 Reinstall compensator piston and valve head assembly to mounting sleeve and reconnect product lines to pre mix containers 9 Draw drinks to flush sanitizing solution left in valve Taste the...

Page 8: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...