![background image](http://html1.mh-extra.com/html/lancer/portion-control/portion-control_operation-manual_672721020.webp)
19. SYRUP SOLENOID ACCESS
19.1 REMOVAL
A. Remove valve from back block (see Valve,
Section 9).
B. Remove circuit board (see Circuit Board,
Section 12).
C. Remove nozzle/diffuser (see Nozzle/ Diffuser,
Section 11).
D. Remove lever arm, if applicable (see Lever
Arm, Section 10).
E. Remove four (4) screws holding the bottom
plate in place.
F. Pull bottom plate off.
G. Remove the two (2) screws that hold the syrup
body in place.
H. Turn valve assembly over and remove the two
(2) screws, on the underside of the main body,
holding the syrup body in place.
I. Lift the syrup body off of the syrup solenoids.
FIGURE 23 - SYRUP SOLENOID ACCESS
O-Ring
Bottom Plate
Screw
Syrup
Syrup Down Tube
Syrup Body
Screw
Screw
Circuit Board
Nozzle
Diffuser
Screw
NOTE: Part Number in ( ) is a Coca-Cola PN
O-Ring
05-2053/01
(24246)
Assembly
54-0176/04
(24245)
02-0005
(10050)
04-0637
(24221)
04-0633/01
(24209)
02-0005
(10050)
05-0960/01
(24244)
Restrictor Assembly
54-0190
(24220)
Subassembly
82-1117/02
(24217)
Solenoid
Subassembly
04-0459
(24242)
64-5040
04-0640
(24208)
(24155)
!
CAUTION
PARTS OF THE SYRUP SOLENOIDS MAY
FALL OUT WHEN THE SYRUP BODY IS REMOVED.
PRECAUCIÓN
PARTES DE LOS SOLENOIDES DEL
JARABE SE PUEDEN CAER CUANDO SE RETIRA EL
CUERPO DEL JARABE.
ATTENTION
CERTAINS COMPOSANTS DES
ÉLECTRO-AIMANTS DU CÔTÉ SIROP POURRONT
TOMBER LORSQUE LE CORPS DE LA VANNE SERA
DÉPOSÉ.
J. Lift each syrup solenoid out of the valve.
NOTE:
The o-ring mounted under neath the
solenoid may stick to the solenoid when it is
removed.
19.2 INSTALLATION
A. Install an o-ring over the port in the bottom of
each syrup solenoid mounting area on the
main body. Ensure that o-ring seats to bottom
of mounting port.
B. Apply 111 Lubricant to the outside edges of the
o-rings.
C. Insert syrup solenoid sub-assembly into the rear mounting area on the main body. Twist the
solenoid while pushing it into place to avoid pinching the o-ring at the bottom of the mounting
area. Turn the solenoid, so that the terminal block rests against the water solenoid retainer
post.
D. Insert syrup solenoid sub-assembly into the front mounting area on the main body. Twist the
solenoid while pushing it into place to avoid pinching the o-ring at the bottom of the mounting
area. Turn the solenoid so that the terminal block rests in groove towards, but not over, the
syrup down tube port.
E. Apply 111 Lubricant around each of the o-rings on the syrup down tube.
!
CAUTION
DO NOT GET LUBRICANT ON THE SPRING OR CORE IN THE SOLENOID.
PRECAUCIÓN
NO PERMITA QUE EL LUBRICANTE SE INTRODUZCA EN EL RESORTE O EN EL CORAZÓN DEL
SOLENOIDE.
ATTENTION
FAIRE ATTENTION DE NE PAS RÉPANDRE DE LA GRAISSE SUR LE RESSORT OU LE NOYEAU-
PLONGEUR DE L’ÉLECTRO-AIMANT.
20