FIGURE 17
13. FLOWMETER
13.1 REMOVAL
A. Remove cover and ID panel (see Cover and
ID Panel, Section 8).
B. Remove valve from back block (see Valve,
Section 9).
C. Remove nozzle/diffuser (see Nozzle/ Diffuser,
Section 11).
D. Remove lever arm, if applicable (see Lever Arm, Section 10).
E. Remove four (4) screws holding the bottom plate in place.
F. Pull bottom plate off.
Screw
Circuit Board
NOTE: Part Number in ( ) is a Coca-Cola PN
04-0640
(24208)
52-2345/05
(24155)
!
CAUTION
USE CARE WHEN REMOVING THE SCREWS TO AVOID
DAMAGING THE FLOWMETER SENSOR WIRES.
PRECAUCIÓN
TENGA CUIDADO CUANDO RETIRE LOS TORNILLOS
PARA EVITAR DAÑAR LOS CABLES DEL SENSOR DEL FLUXÓMETRO.
ATTENTION
LORSQU’IL S’AGIRA DE DÉPOSER LES VIS, IL
CONVIENDRA DE PRENDRE SOIN DE NE PAS ENDOMMAGER LES FILS
DU CAPTEUR DUDÉBITMÈTRE.
!
CAUTION
DO NOT PINCH THE FLOWMETER O-RING DURING INSTALLATION. THE O-RING MUST STAY IN THE
GROOVE ON THE FLOWMETER BODY.
PRECAUCIÓN
NO PELLIZQUE EL ANILLO O- DEL FLUXÓMETRO DURANTE LA INSTALACIÓN. EL ANILLO
O- DEBE MANTENERSE EN LA RANURA SOBRE EL CUERPO DEL FLUXÓMETRO.
ATTENTION
FAIRE ATTENTION DE NE PAS PINCER LE JOINT TORIQUE DU DÉBITMÈTRE LORS DU MONTAGE.
LE JOINT TORIQUE DEVRA RESTER LOGÉ DANS LA RAINURE PRÉVUE SUR LE CORPS DU DÉBITMÈTRE.
!
CAUTION
DO NOT PINCH ANY WIRES WITH THE BOTTOM PLATE.
PRECAUCIÓN
NO PELLIZQUE NINGÚN CABLE CON EL FONDO.
ATTENTION
VEILLER À CE QUE L’EMBASE NE VIENNE PAS PINCER LES FILS.
G. Remove four (4) screws holding the flowmeter body in place.
H. Carefully pull the flowmeter body and o-ring off of the valve.
Use caution to not pull the rotor and bearings out of the
flowmeter body as ball bearings are snapped into place.
13.2 INSTALLATION
A. Place the o-ring in the groove in the flowmeter body.
B. If necessary, carefully apply a small amount of 111 Lubricant to o-ring. NOTE: Do not get
lubricant in the flowmeter.
C. With the wires exiting toward the front of the valve, carefully press the flowmeter sub-assembly
into place on the underside of the valve body. The flat surface of the flowmeter must be flush
against the mounting surface of the valve body.
D. Install four (4) screws to hold the flowmeter in place. Gently position the sensor wires so they
are not pinched or scraped when the screws are installed. NOTE: The flowmeter screws are
5/8” long, and are longer than the bottom plate screws.
E. Thread the connector attached to the flowmeter sensor wires through hole on the valve body
that is in front of flow washer mounting port (see Figure 18).
F. Place the flowmeter sensor wires around the outside of the flow washer mounting port, so that
they will not interfere with the bottom plate installation.
G. Line up holes on the bottom plate with the screw holes on the underside of the valve body. The
raised sections around the screw holes should fit completely in the counterbores on the bottom
plate.
H. Secure bottom plate in place with four (4) screws.
I. Replace nozzle/diffuser and lever arm (if applicable).
J. Install ID panel and cover.
13