6.8 TOP COVER REMOVAL
A. Remove the door.
B. Remove the two outer screws on the top face of each door frame.
NOTE:
There are six screws on the top face of the door frame; however, the middle screw above
each door opening is not used to secure the top cover.
C. Remove the three screws on the back of the top cover that secure the top cover to the frame.
D. Gently work the top cover up and off of the unit, starting at the front and alternating to the back,
until the tabs holding the front of the top cover clear the top to the door frame.
E. Remove the top cover.
F. Replacement is the reverse of removal. Be careful to align the tabs in their respective slots and
work the top cover down into position.
6.9 REFRIGERATION DECK REMOVAL
A. Unplug unit.
B. Remove the door.
C. Remove the top cover.
D. Remove the four screws that secure the deck to the insulated tank assembly (a 3/8” socket and
a long extension are required).
E. Unplug the main power harness from the ice bank control box.
F. Locate a suitable location to place the deck once it is removed, considering that the melting ice
will allow the deck to slide easily.
G. Position yourself on the counter, secure your weight lifting belt, and grasp the lifting handles on
the deck.
H. Using proper lifting techniques, lift the deck straight up until the evaporator and ice bank clear
the top of the wrapper. Place the deck on a suitable location, resting it on the bottom surface of
the ice.
NOTE:
For this step, request assistance if necessary. Lift the deck relatively straight to prevent the
ice bank from wedging against the sides of the tank.
I. Check that the main power harness is secured and out of the way, and replace the deck by
lowering the assembly straight down into the water bath compartment. Check to ensure the
guide pins on the tank line up with the holes in the deck.
J. Secure the deck to the tank with the four screws.
K. Connect the main power harness to the ice bank control box.
L. Replace the top grid and secure with the two screws.
6.10 PRODUCT COMPARTMENT COOLING FAN/COIL REMOVAL
A. Turn key switch to
OFF
position.
B. Unplug unit.
C. Pump water from bath.
D. Remove the concentrate product.
E. Remove nozzle from the water fitting.
F. Remove the pump assemblies.
G. Remove platform base.
H. Tilt the pump assembly platform base forward to disengage pumpbase connectors (2).
I. Remove the two screws that secure the back plate to the back wall of the unit.
J. Lift the plate up slightly while tipping the top edge toward you to disengage the bottom edge
from the tabs on the bottom of the base.
K. Remove the four screws that secure the fan assembly to the back plate.
L. Pull the fan/coil assembly toward the front of the machine to disconnect the top water fitting.
M. Rotate the assembly to provide access to the connector. Unplug the connector and remove the
assembly.
N. Pull the bail on the bottom water fitting toward the front of the machine to disconnect.
O. Replacement is the reverse of removal.
20