background image

1

2

3

4

5

6

7

8

9

10

11

12

17

13

14 15 16

18

19

20

3

21

3

22

23

24

25

26

7. ILLUSTRATIONS, PARTS LISTINGS, AND WIRING DIAGRAMS

7.1

CONTROL BOX ASSEMBLY, FRONT VIEW

Item Part No.

Description

1

51-1421

Control Box Assy, DQ, LFS

2

30-3125

Cover, Control Box, LFS

3

04-0148

Screw, 10 - 32 x 0.250, THD, SL,
MS, SS

4

06-2486/01 Decal, Wiring Diagram, LFS

5

04-1292

Washer, SS, 0.500 ID X 0.870 OD X
0.0300 THK

6

12-0446

Switch, Rocker, Double Pole,
Double Throw

7

06-2483

Label, Switch, LFS

8

06-2484

Label, Power LED, LFS

9

06-2485

Label, Sold Out LED, LFS

10

12-0447

LED, Red, Snap Mount, 5 VDC

11

12-0448

LED, Green, Snap Mount, 5 VDC

12

05-0287/02

Panel, ID. 

LEV

®

, Basic, Lift-Off

13

19-0181/01

LEV

®

, 4.5, W/O C, L, S, WH

(includes back block)

Item Part No.

Description

14 54-0029/01 Cover, Subassy, 

LEV

®

, Lift-Off

15 04-1089

Screw, 10 - 32, RH, PFH/SL, 1.000

16 04-0558

Screw, 10 - 32 x 0.375, LG, PHP,
ROLOC

17 05-2014

Lid, Hopper

18 13-0005

Bushing, Strain Relief, 0.312 OD

19

30-3193

Base, DQ, LFS

20

30-3134

Hinge, Bottom, LFS

21 07-0575

Hinge, SS, Concealed, Removable

22 30-3135

Support, Syrup and Water

23 04-0684

Nut, Hex, Jam, 5/8 - 18, SS, Plain

24 06-0112

Label, Water

25 06-0075-01 Nameplate, Vinyl, PN/SN/ELEC

ONLY

26 13-0028

Relief, Strain, 7/8 DIA

8

Summary of Contents for LEV FILL STATION

Page 1: ...310 7245 ASIA 210 310 7242 EUROPE 32 2 755 2399 PACIFIC 61 8 8268 1978 FAX ENGINEERING 210 310 7096 Lancer is the registered trademark of Lancer Copyright 2001 by Lancer all rights reserved NOTICE TO...

Page 2: ...NG 5 6 1 GREEN POWER LIGHT DOES NOT COME ON 5 6 2 UNDER SOLD OUT CONDITION SOLD OUT ALARM SOUNDS BUT THE RED SOLD OUT LED DOES NOT FLASH 6 6 3 UNIT WILL NOT GO INTO AUTO MODE 6 6 4 SOLD OUT ALARM DOES...

Page 3: ...old Out LED Green Power Power Switch LEV R Opening for Power Cord Three Prong Grounded 3 8 Water Inlet 3 8 Syrup Inlet Introduction to the Lancer LEV Fill Station LFS PN 85 0087 ii Front View LFS Rear...

Page 4: ...ONS 14 5 x 5 5 x 7 5 36 83 cm x 13 97 cm x 19 05 cm ELECTRICAL 115V 60Hz 1 0A Power Cord is provided with three prong grounded plug INLET SYRUP CONNECTIONS 3 8 inch Male Flare INLET WATER CONNECTIONS...

Page 5: ...clamps C Turn on water supply D Open all dispenser valves until air is bled from system E Actuate valve until a smooth flow of water is obtained by holding in Manual Mode F Check for leaks G Connect f...

Page 6: ...used as long as it is prepared in accordance with the manufacturer s written recommendations and safety guidelines and provides 100 PPM available chlorine 3 Cleaning Procedure CAUTION BE CAREFUL NOT T...

Page 7: ...nit into AUTO Mode The Green power light will come on and the valve will start dispensing syrup and water out of the valve 5 4 MANUAL MODE A Switch the unit in MANUAL Mode this requires holding down t...

Page 8: ...Section 5 5 3 Put the Switch in AUTO mode to go into AUTO fill mode The unit should be ready to fill in the AUTO mode again 5 8 FUNCTIONS AND ALARMS A The probes monitor the level of product in the ho...

Page 9: ...O ring is not properly installed A Install or replace o ring correctly nozzle above diffuser B O ring is damaged or missing B Replace o ring 6 8 Leakage between A One or more retaining screws A Tighte...

Page 10: ...E BIB empty E Replace BIB 6 14 Water only dispensed A Water or syrup stem on A Check stems on mounting no syrup or syrup only mounting block not fully block to ensure they are in full dispensed no wat...

Page 11: ...FS 9 06 2485 Label Sold Out LED LFS 10 12 0447 LED Red Snap Mount 5 VDC 11 12 0448 LED Green Snap Mount 5 VDC 12 05 0287 02 Panel ID LEV Basic Lift Off 13 19 0181 01 LEV 4 5 W O C L S WH includes back...

Page 12: ...7 08 0461 Tubing Redline 0 265 x 0 457 TO VALVE TO PRESSURE SWITCH TO SWITCH TO GROUND STUD TO PROBES TO PRIMARY 3 TO SECONDARY 4 6 5 7 8 2 1 TO LED Item Part No Description 1 52 2511 Harness Valve t...

Page 13: ...0V 50 60Hz 24V 50VA 5 04 0504 Screw 8 18 x 0 375 PHD W ELW PH AB 6 03 0095 Spring Outside Yoke 7 03 0342 Ring Retaining 1 8 Shaft External Self Locking Item Part No Description 8 04 1053 Screw Shoulde...

Page 14: ...T SEC 52 2509 TRANSFORMER PRI PRESSURE SWITCH NO COM LO WHT PROBES BLK RED LO 52 2497 BLK WHT LED GRN RED BLK HI NC LED RED BLK RED 11 0180 J7 52 2510 J4 J5 P1 52 2498 J3 J6 PC BOARD 52 2500 J1 52 249...

Page 15: ...i Pakkred Nonthaburi 11120 Thailand Phone 662 961 9543 FAX 662 961 9550 e mail prachat asianet co th Lancer Indian Sub Continent India Shabbir Shafiqui Area Manager India and Sub Continent B 7 Pannala...

Page 16: ...210 310 7000 FAX 210 310 7245 1 800 729 1500 e mail latinamerica lancercorp com Lancer de M xico S A de C V Contact Francisco Lozano Calle Lerdo De Tejada 544 PTE Col Las Villas San Nicolas De Los Ga...

Reviews: